Electronic component and circuit board manufacturers

These manufacturers fabricate bare circuit boards, load them with components on automated assembly lines, and make capacitors, coils, connectors, harnesses and other parts. Plating and etching lines and reflow ovens sit beside dense, costly stock that smoke and water ruin, and the parts end up inside vehicles, aircraft and medical devices.

Manufacturing · NAICS 334418 · SIC 3679 · Updated November 2026

01 / Loss drivers

Where losses come from.

  1. 01

    Fires in plating lines, reflow ovens and lamination presses that smoke-damage costly stock and equipment

  2. 02

    Copper, lead and solvent contamination from etching, plating and decades of wastewater handling

  3. 03

    Board or component defects that force customers into recalls and line stoppages

How it comparesEach line’s rating against the average for its NAICS sector, Manufacturing (178 business types), and for all 747.
  1. PropertyProperty: High, 4 of 5; sector average 3.7; all business types 2.9.
  2. Business interruptionBusiness interruption: High, 4 of 5; sector average 3.5; all business types 2.7.
  3. Premises liabilityPremises liability: Low, 1 of 5; sector average 1.9; all business types 2.7.
  4. Products and completed workProducts and completed work: Elevated, 3 of 5; sector average 3.4; all business types 2.6.
  5. Workers’ injuryWorkers’ injury: Moderate, 2 of 5; sector average 3.4; all business types 3.0.
  6. Commercial autoCommercial auto: Low, 1 of 5; sector average 2.3; all business types 2.5.
  7. Crime and theftCrime and theft: Elevated, 3 of 5; sector average 1.9; all business types 2.2.
  8. Inland marine and equipmentInland marine and equipment: Elevated, 3 of 5; sector average 2.6; all business types 2.6.
  9. EnvironmentalEnvironmental: High, 4 of 5; sector average 2.8; all business types 2.3.
  10. Cyber and dataCyber and data: Elevated, 3 of 5; sector average 2.7; all business types 2.7.
  11. Professional liabilityProfessional liability: Moderate, 2 of 5; sector average 1.5; all business types 2.0.
  12. Umbrella and excessUmbrella and excess: Elevated, 3 of 5; sector average 3.6; all business types 3.6.
What’s changing
  • Electric vehicles and power electronics put boards into high-voltage, high-heat uses, where a defect causes fire and recall rather than a dead device.
  • New plants are opening as customers diversify supply, and unseasoned lines and staff raise early-life fire, quality and contamination losses.
  • Shortages push buyers toward brokers, letting counterfeit and recycled parts into products that may fail years later with weak traceability.
02 / Line by line

Twelve lines, rated.

Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.

Property

High
Heated plastic plating tanks, solvent cleaning, reflow and wave soldering, and hot lamination presses sit close to dense, smoke-sensitive electronic stock.

Fire, explosion, water and weather damage to buildings, contents and stock.

Watch for
  • Immersion heaters in plastic tanks with no low-level cutoff
  • Plastic wet process lines and exhaust ducts without internal sprinklers
  • Customers' components stored in open racking beside production
Controls that matter
  • Low-level and overtemperature cutoffs on all heated tanks
  • Sprinklers inside plastic ducts and wet benches, with early smoke detection
  • Smoke-tight storage rooms for high-value components and finished boards

Business interruption

High
Customers qualify each site and line for automotive, aerospace and medical work, and a plating line or wastewater permit is slow to replace.

How long and how costly a shutdown is.

Watch for
  • Sole qualified source for a customer's safety-critical board
  • One wastewater treatment plant serving every wet process line
  • Specialty laminates or chips available from a single supplier
Controls that matter
  • Qualified sister site or contract partner for key product families
  • Spare rectifiers, pumps and controls held for the wet lines

Premises liability

Low
Plants admit staff, customer auditors and service engineers; the public has no reason to enter.

Injuries to customers and the public, on site or caused by operations elsewhere.

Watch for
  • Shared multi-tenant buildings with common ventilation
Controls that matter
  • Visitor escort and a chemical release plan shared with neighbors

Products and completed work

Elevated
Components rarely injure anyone directly, but a solder defect or failed capacitor in a vehicle or device triggers recalls and occasional fires.

Harm caused by what the business sells, serves, makes, installs or repairs.

Watch for
  • Boards for vehicle safety systems, medical devices or aircraft
  • Components bought through brokers during shortages
  • Contracts accepting recall and line-stoppage costs without a cap
Controls that matter
  • Lot traceability from incoming parts through test to each shipped board
  • Approved distributor lists and counterfeit screening for brokered parts
  • Automated optical and X-ray inspection with retained test records

Workers’ injury

Moderate
Assembly is light, clean work; board fabrication adds acid, formaldehyde and solder fume exposures, and inspection is repetitive.

Injuries and illness to employees.

Watch for
  • Manual handling of etchants and plating chemicals
  • Hand soldering and rework without fume extraction
Controls that matter
  • Eyewash, showers and chemical-specific protective equipment at wet lines
  • Fume extraction at soldering, rework and conformal coating stations

Commercial auto

Low
Product ships by courier and carrier; staff drive only for sales calls and the odd local delivery.

Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.

Watch for
  • Local delivery runs to customers by staff in own cars
Controls that matter
  • Hired and non-owned auto cover with driving record checks

Crime and theft

Elevated
Gold and palladium plating salts, high-value chips and finished boards are compact, and counterfeit parts can enter through the supply chain.

Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.

Watch for
  • Precious metal salts issued without weighing and reconciliation
  • Kitted components moving between stores and lines without counts
Controls that matter
  • Caged component stores with logged access and cycle counts
  • Precious metal chemistry locked and reconciled against plating output

Inland marine and equipment

Elevated
Contract assemblers hold customer-owned components and boards, often worth more than their own stock, and air shipments carry high values.

Property in transit, at job sites or in the insured’s care, and mobile equipment.

Watch for
  • Consigned customer parts with no agreed values or limits
  • Moisture-sensitive components stored without dry cabinets
Controls that matter
  • Bailee cover sized to peak values of customers' consigned parts
  • Transit limits reviewed against the largest air shipment

Environmental

High
Board fabrication runs copper, lead, nickel, ammonia and formaldehyde through etching, plating and wastewater treatment, and older sites carry solvent contamination.

Pollution on or from the site or the work.

Watch for
  • Bare board etching or connector plating on site, not assembly only
  • History of vapor degreasing or solvent board cleaning
  • Wastewater discharge violations or treatment near capacity
Controls that matter
  • Bermed, sealed containment with leak detection under every wet line
  • Continuous pH and metals monitoring before discharge
  • Baseline soil and groundwater study before binding older sites

Cyber and data

Elevated
Customers' designs, defense drawings and traceability data sit on networked assembly lines that stop when ransomware strikes.

Data breaches, ransomware, system outages and attacks on connected equipment.

Watch for
  • Customer design files shared over email or unmanaged portals
  • Assembly machines on the same network as office systems
Controls that matter
  • Segmented production network with offline backups of programs and data
  • Controlled file transfer and access logs for customer designs

Professional liability

Moderate
Some firms design layouts, choose components or write test programs for customers, and errors there cause failures and redesign costs.

Loss or injury caused by advice, design, testing, care or another professional service.

Watch for
  • Board layout or component selection sold as a design service
Controls that matter
  • Design work under written scope with customer approval of each revision

Umbrella and excess

Elevated
A component defect spread across many vehicles or devices can cause fires or crashes, though most losses are recall and economic.

How likely one liability event is to exhaust primary limits.

Watch for
  • Boards in airbag, braking, battery management or life-support systems
  • Customer contracts with uncapped indemnities
Controls that matter
  • Application limits and indemnity caps written into sales terms
  • Failure analysis and containment started within days of a complaint
03 / Property picture

Construction, occupancy, protection, exposure.

What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.

Construction
Single-story steel or tilt-up buildings, often in industrial parks, with clean assembly areas, chemical rooms and wastewater plants added as lines grew.
Occupancy
Plating, etching and drilling of boards, lamination presses, automated placement, reflow and wave soldering, coating and testing, with dense, smoke-sensitive components and finished goods.
Protection
Sprinklers throughout, including inside plastic ducts and wet benches, very early smoke detection, segregated chemical storage, monitored alarms and controlled access to component stores.
Exposure
Multi-tenant parks and shared walls let smoke or a chemical release travel between units, and a neighbor's fire can ruin smoke-sensitive stock without spreading flame.
04 / Checklist

What to ask and look for.

Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.

Before quoting: ask the broker or owner

Documents to request

On site: processes

On site: protection and storage

On site: quality and supply

On site: environment and records

Refer or decline if you find

  • Heated plastic tanks without low-level or overtemperature cutoffs
  • Unsprinklered plastic exhaust ducts or wet benches
  • Open wastewater violation or unfunded groundwater cleanup
  • Brokered components used without counterfeit screening
  • Customers' consigned stock with no inventory or agreed values
05 / Location

How UrbanStat data helps.

Water, humidity and smoke ruin electronics, so flood and wind-driven rain cause large stock losses. Plants cluster in some seismic regions, power outages after hurricanes stop lines, and compact high-value stock draws theft.

FloodEarthquakeHurricaneWindCrime
  • Flood scores at the address show whether wet process lines, wastewater plants and smoke-sensitive stock on ground floors sit in water's path.
  • Earthquake scores at the address show how exposed plating tanks, chemical piping and precision placement lines are to shaking before property terms are set.
  • Crime scores at the address inform terms for precious metal chemistry, high-value chips and finished boards held on site.
Flood · Earthquake · Hurricane · Wind
06 / Public loss data

What the published numbers say.

Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.

Workers’ injury frequency

0.9 recordable injuries and illnesses per 100 full-time workers, below the private-industry average of 2.3.

Printed circuit assembly (electronic assembly) manufacturing
0.9
All private industry
2.3

0.4 of these cases per 100 workers involved days away from work.

United States, 2024. Industry: Printed circuit assembly (electronic assembly) manufacturing (NAICS 334418). Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.

Workplace deaths

9 fatal work injuries in 2024.

Manufacturing
2.4
All workers
3.3

Deaths per 100,000 full-time equivalent workers, for the industry sector as a whole.

United States, private industry, 2024. Industry: Computer and Electronic Product Manufacturing (NAICS 334), the closest published group. Source: U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries; sector rates.

Most cited safety standards

32 citations from 6 inspections; 62% were classed serious, willful or repeat.

  • 1910.107 Spray finishing using flammable and combustible materials
    5
  • 1910.147 The control of hazardous energy (lockout/tagout)
    4
  • 1910.217 Mechanical power presses
    3
  • 1910.1200 Hazard communication
    3
  • 1910.212 General requirements for all machines
    2

Standards cited most often in this industry, by number of citations.

United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Printed Circuit Assembly (Electronic Assembly) Manufacturing (NAICS 334418). Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).

Fire frequency

7,966 fires a year reported in industrial and manufacturing properties, causing about $810 million in direct property damage a year.

United States, 2020 to 2024, annual average. The group includes utility, defense, agriculture and mining properties. Source: National Fire Protection Association, Structure Fires in Industrial and Manufacturing Properties.

Toxic chemical releases

118 facilities reported toxic chemical releases totaling 17,811 pounds on and off site.

  • Copper and copper compounds
    9,365
  • Lead
    5,039
  • Ammonia
    1,988

Chemicals released in the largest amounts, in pounds. 88 of the facilities reported at least one chemical classed as a carcinogen.

United States, 2024. Industry: Printed Circuit Assembly (Electronic Assembly) Manufacturing (NAICS 334418). Covers facilities in listed industries with ten or more full-time employees that handle listed chemicals above set thresholds. Source: U.S. Environmental Protection Agency, Toxics Release Inventory basic data files.

Industry loss ratios by line2020 to 2024, the same table on every guide

Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.

Published lineClosest line in this guide20202021202220232024
FireProperty63.2%67.3%62.4%45.5%40.9%
Commercial multiple perilProperty and liability sold as a package61.2%60.2%59.4%61.2%54.4%
Inland marineInland marine and equipment64.5%49.4%47.1%44.1%44.0%
Other liabilityPremises liability, and most umbrella, professional (other than medical) and cyber cover65.1%58.8%61.0%63.7%71.2%
Products liabilityProducts and completed work48.2%52.2%46.0%57.5%60.3%
Workers’ compensationWorkers’ injury47.9%49.2%45.0%44.3%46.0%
Commercial auto liabilityCommercial auto68.3%66.5%71.9%76.8%77.6%
Commercial auto physical damageCommercial auto50.9%56.3%64.3%65.1%57.9%

United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.

Coverages to raise
Contingent business interruption
Specialty laminates, chips and precious metal chemistry come from few suppliers, and their shortages halt assembly.
Product recall
A board defect forces customers to recall vehicles or devices, and contracts often pass the cost back.
Equipment breakdown
Placement machines, reflow ovens, lamination presses and rectifiers fail electrically and stop qualified lines.
Pollution legal liability
General liability excludes most pollution, and older board fabrication sites often carry solvent and metals contamination.
Classification
SystemCodeIndustry
NAICS 2022, primary334418Printed Circuit Assembly (Electronic Assembly) Manufacturing
NAICS 2022334412Bare Printed Circuit Board Manufacturing
NAICS 2022334416Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing
NAICS 2022334417Electronic Connector Manufacturing
NAICS 2022334419Other Electronic Component Manufacturing
SIC 1987, primary3679Electronic Components, NEC
SIC 19873672Printed Circuit Boards
SIC 19873677Electronic Coils, Transformers, and Other Inductors
SIC 19873678Electronic Connectors
Next step

See this risk on the map.

Book a 30-minute walkthrough tailored to your portfolio and perils of interest.