Lead-acid battery manufacturersNAICS 335910 · SIC 3691

Lead-acid battery makers cast lead grids, paste them with lead oxide, assemble plates into plastic cases, fill with sulfuric acid and charge them. Lead dust and fume reach workers and neighbors, charging gives off hydrogen, and acid and lead end up in floors, drains and soil.

NAICS 335910 Battery ManufacturingSIC 3691 Storage Batteries

Manufacturing · Updated November 2026

01 / Loss drivers

Where losses come from.

  1. 01

    Lead contamination of soil, dust and water on and around the site

  2. 02

    Lead poisoning, acid burns and lifting injuries among production workers

  3. 03

    Fires in plastic cases, charging rooms and dust collectors

How it comparesEach line’s rating against the average for its NAICS sector, Manufacturing (178 business types), and for all 747.
  1. PropertyProperty: High, 4 of 5; sector average 3.7; all business types 2.9.
  2. Business interruptionBusiness interruption: Elevated, 3 of 5; sector average 3.5; all business types 2.7.
  3. Premises liabilityPremises liability: Moderate, 2 of 5; sector average 1.9; all business types 2.7.
  4. Products and completed workProducts and completed work: Elevated, 3 of 5; sector average 3.4; all business types 2.6.
  5. Workers’ injuryWorkers’ injury: High, 4 of 5; sector average 3.4; all business types 3.0.
  6. Commercial autoCommercial auto: Elevated, 3 of 5; sector average 2.3; all business types 2.5.
  7. Crime and theftCrime and theft: Moderate, 2 of 5; sector average 1.9; all business types 2.2.
  8. Inland marine and equipmentInland marine and equipment: Moderate, 2 of 5; sector average 2.6; all business types 2.6.
  9. EnvironmentalEnvironmental: Severe, 5 of 5; sector average 2.8; all business types 2.3.
  10. Cyber and dataCyber and data: Moderate, 2 of 5; sector average 2.7; all business types 2.7.
  11. Professional liabilityProfessional liability: Low, 1 of 5; sector average 1.5; all business types 2.0.
  12. Umbrella and excessUmbrella and excess: High, 4 of 5; sector average 3.6; all business types 3.6.
What’s changing
  • Vehicles and standby systems are shifting to lithium-ion, so lead-acid plants face falling volumes, aging equipment and pressure to cut maintenance.
  • Lower permitted blood lead and air emission limits raise compliance costs and give former workers and neighbors grounds for exposure claims.
  • More makers run closed-loop recycling of spent batteries, adding smelting, slag and scrap yard exposure to the manufacturing risk.
02 / Line by line

Twelve lines, rated.

Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.

Property

High
Molten lead pots, oxide mills, hydrogen from formation charging, rectifiers and stacks of polypropylene cases share an acid-corroded building.

Fire, explosion, water and weather damage to buildings, contents and stock.

Watch for
  • Formation rooms with weak ventilation or no hydrogen detection
  • Plastic cases and pallets stored against the charging area
  • Baghouses and ducts with corroded or disabled spark protection
Controls that matter
  • Mechanical ventilation and hydrogen detection interlocked with chargers
  • Sprinklers with corrosion-resistant heads, inspected often
  • Temperature controls and containment on lead pots and oxide mills

Business interruption

Elevated
Pasting, casting and formation lines are specialized but obtainable, and an emissions violation can close the plant by order.

How long and how costly a shutdown is.

Watch for
  • A single oxide mill or pasting line for all production
  • Operating permit conditions close to their limits
Controls that matter
  • Spare capacity or toll arrangements for oxide and grids
  • Emission controls with redundancy and continuous monitoring

Premises liability

Moderate
Visitors are few, but lead dust carried beyond the fence brings injury claims from neighbors, especially for children.

Injuries to customers and the public, on site or caused by operations elsewhere.

Watch for
  • Homes, schools or playgrounds near the plant boundary
  • Workers leaving in contaminated clothing and vehicles
Controls that matter
  • Fence-line air monitoring with results on file
  • Mandatory showers and laundered workwear before leaving site

Products and completed work

Elevated
Batteries explode when hydrogen ignites during charging or jump starting, and cracked cases leak acid onto people and property.

Harm caused by what the business sells, serves, makes, installs or repairs.

Watch for
  • Vent and flame arrestor design changes without retesting
  • Large industrial or standby batteries installed in occupied buildings
Controls that matter
  • Flame-arresting vents and leak testing on every battery
  • Charging, handling and eye protection warnings molded into the case

Workers’ injury

High
Lead absorption is a constant occupational disease exposure, joined by acid burns, molten metal splashes and heavy repetitive lifting.

Injuries and illness to employees.

Watch for
  • Blood lead results trending upward or workers on medical removal
  • Dry sweeping or compressed air used for cleanup
  • Eating or smoking areas not separated from production
Controls that matter
  • Enclosed, ventilated pasting, casting and assembly stations
  • Routine blood lead testing with removal thresholds enforced
  • Clean and dirty change rooms, showers and vacuum cleaning

Commercial auto

Elevated
Route trucks deliver heavy, acid-filled batteries to dealers and bring back spent ones for recycling.

Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.

Watch for
  • Spent batteries hauled loose or stacked without containment
  • Overloaded trucks on multi-stop daily routes
Controls that matter
  • Acid-resistant, contained cargo areas and secured pallets
  • Drivers trained in hazardous cargo and spill response

Crime and theft

Moderate
Lead ingots, copper and scrap batteries are heavy but sell readily to scrap dealers.

Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.

Watch for
  • Scrap batteries and lead stored in an unfenced yard
Controls that matter
  • Fenced, lit yard and weighbridge records for all metal movements

Inland marine and equipment

Moderate
Shipments are dense and hazardous; a shifted load cracks cases and spills acid in the trailer.

Property in transit, at job sites or in the insured’s care, and mobile equipment.

Watch for
  • Mixed freight loaded above or beside filled batteries
Controls that matter
  • Palletized, shrink-wrapped loads with terminal protection and spill kits

Environmental

Severe
Lead oxide dust, stack emissions, acid wash-down and decades of spills contaminate soil and groundwater, with cleanup costs that dwarf the plant's value.

Pollution on or from the site or the work.

Watch for
  • No recent soil, dust and groundwater sampling on and off site
  • Unlined yards used for scrap batteries or slag
  • Stormwater leaving the site untreated
Controls that matter
  • Baghouses with leak detection and continuous stack monitoring
  • Paved, contained process and storage areas draining to treatment
  • Wastewater neutralized and lead removed before discharge, with records

Cyber and data

Moderate
Casting, pasting and formation lines use ordinary controls and the data held is modest, though an outage delays orders and emissions records.

Data breaches, ransomware, system outages and attacks on connected equipment.

Watch for
  • Formation charger controls reachable from the office network
  • Emissions monitoring data held on one unprotected server
Controls that matter
  • Offline backups of machine programs and emissions records
  • Multi-factor login for remote access and email

Professional liability

Low
Batteries are standard products; sizing advice for standby systems is incidental to the sale.

Loss or injury caused by advice, design, testing, care or another professional service.

Watch for
  • Standby battery system sizing or installation design for customers
Controls that matter
  • Design work done by qualified engineers under written terms

Umbrella and excess

High
Lead exposure claims from neighboring families, a hazardous cargo crash or a battery explosion can each produce severe, many-claimant losses.

How likely one liability event is to exhaust primary limits.

Watch for
  • Homes, schools or daycares close to the fence line
  • Route trucks carrying filled and spent batteries every day
Controls that matter
  • Fence-line monitoring and dust control, with records kept
  • Driver selection, telematics and spill training for the route fleet
03 / Property picture

Construction, occupancy, protection, exposure.

What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.

Construction
Older single-story steel or masonry plants, often extended many times, with acid-resistant floors, corroded steel and electrical gear, and baghouses and stacks outside.
Occupancy
Molten lead casting, oxide milling, pasting, acid filling and formation charging that gives off hydrogen, beside stacks of polypropylene cases, separators and wooden pallets.
Protection
Sprinklers with corrosion-resistant heads, hydrogen detection interlocked with chargers, spark detection on baghouses, paved and contained yards, and a fenced, lit perimeter.
Exposure
Many plants sit near older housing; lead dust, acid runoff and smoke travel to neighbors, and scrap battery yards attract theft and spread fire.
04 / Checklist

What to ask and look for.

Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.

Before quoting: ask the broker or owner

Documents to request

On site: operations

On site: environment

On site: worker health

On site: fire protection and fleet

Refer or decline if you find

  • No environmental site assessment for a long-established plant
  • Housing or a school adjoining the boundary with no air monitoring
  • Rising blood lead levels or repeated medical removals
  • Spent batteries stacked on bare ground
  • Formation charging with no hydrogen detection or ventilation interlock
05 / Location

How UrbanStat data helps.

Flood or storm runoff through a lead-acid plant carries lead and acid into neighboring land and waterways. Wind damage to baghouses and stacks releases dust, and how close homes and schools sit decides the size of any claim.

FloodHurricaneWindTornadoEarthquake
  • Flood scores at the address show whether floodwater could carry lead and acid from yards and process floors onto neighboring land.
  • Parcel and permit data give the construction date and permit history, a first pointer to how many decades lead has been handled on the site.
  • Underwriting rules drawn on the map can refer any lead-acid plant inside a flood or hurricane zone before terms are offered.
Flood · Hurricane · Wind · Tornado
06 / Public loss data · NAICS 335910

What the published numbers say.

Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.

Workers’ injury frequency

2.7 recordable injuries and illnesses per 100 full-time workers, close to the private-industry average of 2.3.

Battery manufacturing
2.7
All private industry
2.3

1.0 of these cases per 100 workers involved days away from work.

United States, 2024. Industry: Battery manufacturing (NAICS 33591), the closest published group. Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.

Workplace deaths

5 fatal work injuries in 2024.

Manufacturing
2.4
All workers
3.3

Deaths per 100,000 full-time equivalent workers, for the industry sector as a whole.

United States, private industry, 2024. Industry: Electrical Equipment, Appliance, and Component Manufacturing (NAICS 335), the closest published group. Source: U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries; sector rates.

Most cited safety standards

239 citations from 73 inspections; 55% were classed serious, willful or repeat.

  • 1910.1025 Lead
    25
  • 1910.1200 Hazard communication
    24
  • 1910.134 Respiratory protection
    22
  • 1910.147 The control of hazardous energy (lockout/tagout)
    21
  • 1910.212 General requirements for all machines
    20

Standards cited most often in this industry, by number of citations.

United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Other Electrical Equipment and Component Manufacturing (NAICS 3359), the closest published group. Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).

Fire frequency

7,966 fires a year reported in industrial and manufacturing properties, causing about $810 million in direct property damage a year.

United States, 2020 to 2024, annual average. The group includes utility, defense, agriculture and mining properties. Source: National Fire Protection Association, Structure Fires in Industrial and Manufacturing Properties.

Toxic chemical releases

76 facilities reported toxic chemical releases totaling 8.1 million pounds on and off site.

  • N-methyl-2-pyrrolidone
    1.9M
  • Cobalt and cobalt compounds
    1.1M
  • Nickel and nickel compounds
    985,106

Chemicals released in the largest amounts, in pounds. 38 of the facilities reported at least one chemical classed as a carcinogen.

United States, 2024. Industry: Battery Manufacturing (NAICS 335910). Covers facilities in listed industries with ten or more full-time employees that handle listed chemicals above set thresholds. Source: U.S. Environmental Protection Agency, Toxics Release Inventory basic data files.

Industry loss ratios by line2020 to 2024, the same table on every guide

Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.

Published lineClosest line in this guide20202021202220232024
FireProperty63.2%67.3%62.4%45.5%40.9%
Commercial multiple perilProperty and liability sold as a package61.2%60.2%59.4%61.2%54.4%
Inland marineInland marine and equipment64.5%49.4%47.1%44.1%44.0%
Other liabilityPremises liability, and most umbrella, professional (other than medical) and cyber cover65.1%58.8%61.0%63.7%71.2%
Products liabilityProducts and completed work48.2%52.2%46.0%57.5%60.3%
Workers’ compensationWorkers’ injury47.9%49.2%45.0%44.3%46.0%
Commercial auto liabilityCommercial auto68.3%66.5%71.9%76.8%77.6%
Commercial auto physical damageCommercial auto50.9%56.3%64.3%65.1%57.9%

United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.

Coverages to raise
Pollution legal liability
Lead in soil, dust and groundwater on and off site is excluded from general liability and slow to clean up.
Transportation pollution liability
Acid spills and lead releases from route trucks carrying filled and spent batteries fall outside standard auto cover.
Equipment breakdown
Oxide mills, casting machines, rectifiers and baghouses fail without fire, and a baghouse failure can halt production by order.
Product recall
A vent, seal or case defect across a production run can force a recall from dealers and fleets.

NAICS and SIC codes for lead-acid battery manufacturers

SystemCodeIndustry
NAICS 2022, primary335910Battery Manufacturing
SIC 1987, primary3691Storage Batteries
Next step

See this risk on the map.