Insulation contractors
Insulation contractors install batts, blown cellulose and fiberglass, rigid board and spray polyurethane foam in buildings, and lag pipes, ducts and equipment. Spray foam brings reactive chemicals and fire risk during application, while retrofit work in old attics and walls meets wiring, vermiculite and asbestos.
Where losses come from.
- 01
Fires during and after spray foam application, and from insulation packed over hot fixtures and old wiring
- 02
Odor, off-gassing and moisture problems that make a finished building unlivable
- 03
Falls through ceilings and respiratory injury to installers
- PropertyProperty: Elevated, 3 of 5; sector average 2.2; all business types 2.9.
- Business interruptionBusiness interruption: Moderate, 2 of 5; sector average 1.8; all business types 2.7.
- Premises liabilityPremises liability: Elevated, 3 of 5; sector average 3.5; all business types 2.7.
- Products and completed workProducts and completed work: High, 4 of 5; sector average 3.8; all business types 2.6.
- Workers’ injuryWorkers’ injury: Elevated, 3 of 5; sector average 3.8; all business types 3.0.
- Commercial autoCommercial auto: Elevated, 3 of 5; sector average 3.1; all business types 2.5.
- Crime and theftCrime and theft: Low, 1 of 5; sector average 1.7; all business types 2.2.
- Inland marine and equipmentInland marine and equipment: Elevated, 3 of 5; sector average 3.2; all business types 2.6.
- EnvironmentalEnvironmental: Elevated, 3 of 5; sector average 2.5; all business types 2.3.
- Cyber and dataCyber and data: Moderate, 2 of 5; sector average 2.0; all business types 2.7.
- Professional liabilityProfessional liability: Moderate, 2 of 5; sector average 2.3; all business types 2.0.
- Umbrella and excessUmbrella and excess: High, 4 of 5; sector average 4.0; all business types 3.6.
- Tighter energy codes and incentives push more spray foam and dense-pack retrofit work, raising both fire and moisture claims on completed jobs.
- Lower-emission foam blowing agents and new chemistries change handling and cure behavior, so crews trained on older products make mistakes.
- Growing awareness of isocyanate sensitization and indoor air quality brings more occupant illness claims after spraying in occupied homes.
Twelve lines, rated.
Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.
Property
ElevatedFoam board, facings and drums of foam chemicals make a combustible warehouse, and spray rigs park inside overnight.
Fire, explosion, water and weather damage to buildings, contents and stock.
- Spray rigs with heated hoses and generators stored indoors beside stock
- Foam board and bagged cellulose stacked to the roof
- Drums of isocyanate and resin kept without containment
- Rigs parked outside or in a separated bay, with power off
- Storage height held within the sprinkler system's design
- Chemical drums on containment pallets at the stated storage temperature
Business interruption
ModerateMaterials are restocked quickly, but a lost spray rig takes months to replace in busy markets.
How long and how costly a shutdown is.
- One or two rigs earning most of the revenue
- Single foam chemical supplier
- Rigs parked apart so one fire cannot take all
- Rental or subcontract capacity arranged in advance
Premises liability
ElevatedSpray foam drifts onto cars and neighbors, fumes require occupants to leave, and foam sprayed too thick can self-heat and ignite.
Injuries to customers and the public, on site or caused by operations elsewhere.
- Exterior or roof spraying in wind near parked vehicles
- Occupants allowed back before the stated re-entry time
- Thick passes applied to hit a deadline
- Pass thickness limits followed, with cure time between lifts
- Written re-entry and ventilation instructions signed by the occupant
- Masking, wind limits and overspray recovery arrangements
Products and completed work
HighOff-ratio foam smells for years, buried light fixtures and old wiring overheat, and badly placed insulation traps moisture and rots framing.
Harm caused by what the business sells, serves, makes, installs or repairs.
- Foam left exposed without the required thermal or ignition barrier
- Insulation blown over recessed lights, knob-and-tube wiring or flue pipes
- Roof decks and crawlspaces sealed without a moisture design
- Installer certification from the foam manufacturer; ratio and temperature logs per job
- Pre-work survey of wiring, fixtures, flues and ventilation
- Barrier coatings applied and photographed before handover
Workers’ injury
ElevatedInstallers crawl through hot attics and tight crawlspaces, step between joists, and breathe fibers and isocyanate vapor.
Injuries and illness to employees.
- Spray foam applied without supplied-air respirators
- Attic work in summer heat with no time limits
- Stepping off joists onto bare ceiling board
- Supplied-air respirators and full skin cover for sprayers and helpers
- Crawl boards in attics and planned heat breaks
- Medical surveillance for isocyanate sensitization
Commercial auto
ElevatedBox trucks and trailers carrying heated chemical tanks, generators and blowers go to a job site daily.
Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.
- Heavy spray rig trailers towed by light trucks
- Chemicals transported without securing or documentation
- Tow ratings checked and drivers trained on trailers
- Drums secured; spill kit and extinguisher on each rig
- Hired and non-owned auto cover for estimators driving their own cars
Crime and theft
LowCustomers pay by invoice or card and the materials have little resale value.
Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.
- Generators and compressors on rigs parked on the street
- Rigs locked and parked in a fenced yard
Inland marine and equipment
ElevatedA spray rig is a truck or trailer packed with proportioner, heated hoses, generator and compressor, and it is the business.
Property in transit, at job sites or in the insured’s care, and mobile equipment.
- Rigs valued well below replacement cost
- Fire originating in the rig's own heaters or generator
- Each rig scheduled at current replacement value
- Extinguishers and shutdown checklist on board
Environmental
ElevatedRetrofit work disturbs asbestos and vermiculite, and spray chemicals, overspray and waste drums need controlled handling.
Pollution on or from the site or the work.
- Old pipe lagging, boiler wrap or vermiculite attic fill removed by the crew
- Empty isocyanate drums discarded without neutralizing
- Suspect materials sampled before work, with licensed abatement where positive
- Waste chemicals and drums returned through the supplier or a licensed hauler
Cyber and data
ModerateOnline leads, financing and energy-program paperwork put homeowners' personal and income data on the firm's systems.
Data breaches, ransomware, system outages and attacks on connected equipment.
- Rebate or weatherization applications holding income records sent by email
- Estimating and scheduling on one laptop with no backup
- Customer files on a managed system with multi-factor login
- Daily backups of estimating, scheduling and job photo records
Professional liability
ModerateEnergy audits, moisture advice and foam specifications are relied on by owners; bad advice leads to condensation, rot or failed energy savings.
Loss or injury caused by advice, design, testing, care or another professional service.
- Energy audits or blower-door testing sold as a separate service
- Unvented attic or crawlspace conversions designed by the installer
- Certified energy auditors and written report templates
- Moisture design checked by an engineer or designer for unusual assemblies
Umbrella and excess
HighA spray foam fire can destroy a large building, and off-gassing claims can involve whole families or many units.
How likely one liability event is to exhaust primary limits.
- Spray foam in occupied multifamily buildings, schools or hospitals
- Tract or condominium contracts with the same foam detail repeated
- Limits sized to the largest building sprayed
- Ignition barriers and re-entry rules enforced the same way on every job
Construction, occupancy, protection, exposure.
What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.
- Construction
- Usually a single-story metal or masonry warehouse with truck bays for spray rigs and blowing trucks, often in a light industrial park.
- Occupancy
- Stock of foam board, faced batts, bagged cellulose and drums of foam chemicals, with rigs parked inside; foam plastics make it burn hot and fast.
- Protection
- Sprinklers designed for foam plastic storage, monitored alarms, rigs in a separated bay or outside, and chemical drums kept at the stated temperature.
- Exposure
- Shared walls in multi-tenant parks let a foam fire spread to neighbors; on job sites, overspray reaches cars and neighboring houses.
What to ask and look for.
Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.
Before quoting: ask the broker or owner
Documents to request
On site: work performed
On site: job sites
On site: people and equipment
On site: records and history
Refer or decline if you find
- Spray foam applied by crews with no manufacturer training
- No job logs of foam ratio, temperature and thickness
- Exposed foam left without a fire barrier
- Vermiculite or asbestos insulation disturbed without testing
- Spray rigs stored inside the warehouse with stock
How UrbanStat data helps.
Fibrous and cellulose stock is ruined by any water, and a warehouse of foam board burns fiercely if wildfire embers or a neighboring fire reach it. Rigs parked outside carry generators and compressors thieves want.
- Flood scores at the warehouse address show whether bagged and fibrous stock that cannot be dried sits in water's path.
- Wildfire scores at the address indicate whether a building full of foam plastics lies within reach of embers.
- Crime scores at the yard address inform theft terms for spray rigs, generators and compressors parked outside.
What the published numbers say.
Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.
2.9 recordable injuries and illnesses per 100 full-time workers, above the private-industry average of 2.3.
1.2 of these cases per 100 workers involved days away from work.
United States, 2024. Industry: Drywall and insulation contractors (NAICS 23831), the closest published group. Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.
17 fatal work injuries in 2024, most often from falls, slips and trips (10).
Deaths per 100,000 full-time equivalent workers, for the industry sector as a whole.
United States, private industry, 2024. Industry: Drywall and Insulation Contractors (NAICS 23831), the closest published group. Source: U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries; sector rates.
874 citations from 317 inspections; 57% were classed serious, willful or repeat.
- 1926.451 General requirements (scaffolds)72
- 1926.501 Duty to have fall protection58
- 1910.134 Respiratory protection50
- 1910.1200 Hazard communication31
- 1926.1053 Ladders30
Standards cited most often in this industry, by number of citations.
United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Drywall and Insulation Contractors (NAICS 238310). Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).
Industry loss ratios by line2020 to 2024, the same table on every guide
Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.
| Published line | Closest line in this guide | 2020 | 2021 | 2022 | 2023 | 2024 |
|---|---|---|---|---|---|---|
| Fire | Property | 63.2% | 67.3% | 62.4% | 45.5% | 40.9% |
| Commercial multiple peril | Property and liability sold as a package | 61.2% | 60.2% | 59.4% | 61.2% | 54.4% |
| Inland marine | Inland marine and equipment | 64.5% | 49.4% | 47.1% | 44.1% | 44.0% |
| Other liability | Premises liability, and most umbrella, professional (other than medical) and cyber cover | 65.1% | 58.8% | 61.0% | 63.7% | 71.2% |
| Products liability | Products and completed work | 48.2% | 52.2% | 46.0% | 57.5% | 60.3% |
| Workers’ compensation | Workers’ injury | 47.9% | 49.2% | 45.0% | 44.3% | 46.0% |
| Commercial auto liability | Commercial auto | 68.3% | 66.5% | 71.9% | 76.8% | 77.6% |
| Commercial auto physical damage | Commercial auto | 50.9% | 56.3% | 64.3% | 65.1% | 57.9% |
United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.
- Contractors' pollution liability
- Disturbed asbestos and vermiculite, isocyanate overspray and off-gassing are pollution claims that general liability often excludes.
- Equipment breakdown
- A failed proportioner, heater or generator idles a spray rig and its crew until parts arrive.
- Installation floater
- Foam board, batts and chemical drums staged at job sites are lost to fire, water or theft before acceptance.
See this risk on the map.
Book a 30-minute walkthrough tailored to your portfolio and perils of interest.