Dental laboratoriesNAICS 339116 · SIC 8072

Dental laboratories make crowns, bridges, dentures, implant parts and orthodontic appliances to dentists' prescriptions, using casting furnaces, porcelain ovens, acrylics and increasingly milling machines and 3D printers. Open flames and flammable monomer in small workshops cause fires, and dust and fumes harm technicians.

NAICS 339116 Dental LaboratoriesSIC 8072 Dental Laboratories

Manufacturing · Updated November 2026

01 / Loss drivers

Where losses come from.

  1. 01

    Bench fires from torches, burnout furnaces and flammable acrylic monomer

  2. 02

    Technician illness from silica, metal and acrylic dust, and burns and cuts

  3. 03

    Remakes and injury claims from ill-fitting or wrongly specified restorations

How it comparesEach line’s rating against the average for its NAICS sector, Manufacturing (178 business types), and for all 747.
  1. PropertyProperty: Elevated, 3 of 5; sector average 3.7; all business types 2.9.
  2. Business interruptionBusiness interruption: Moderate, 2 of 5; sector average 3.5; all business types 2.7.
  3. Premises liabilityPremises liability: Low, 1 of 5; sector average 1.9; all business types 2.7.
  4. Products and completed workProducts and completed work: Elevated, 3 of 5; sector average 3.4; all business types 2.6.
  5. Workers’ injuryWorkers’ injury: Elevated, 3 of 5; sector average 3.4; all business types 3.0.
  6. Commercial autoCommercial auto: Moderate, 2 of 5; sector average 2.3; all business types 2.5.
  7. Crime and theftCrime and theft: Moderate, 2 of 5; sector average 1.9; all business types 2.2.
  8. Inland marine and equipmentInland marine and equipment: Moderate, 2 of 5; sector average 2.6; all business types 2.6.
  9. EnvironmentalEnvironmental: Moderate, 2 of 5; sector average 2.8; all business types 2.3.
  10. Cyber and dataCyber and data: Elevated, 3 of 5; sector average 2.7; all business types 2.7.
  11. Professional liabilityProfessional liability: Moderate, 2 of 5; sector average 1.5; all business types 2.0.
  12. Umbrella and excessUmbrella and excess: Moderate, 2 of 5; sector average 3.6; all business types 3.6.
What’s changing
  • Intraoral scanning, milling and resin printing replace much hand work, cutting dust and burns but adding costly equipment, software dependence and resin chemical exposure.
  • Dental groups and service organizations consolidate buying, so a lab often relies on fewer, larger clients and faces tighter contract and indemnity terms.
  • Low-cost offshore and remote design competition pressures labs to outsource, which raises questions about material origin, disclosure and who answers for defects.
02 / Line by line

Twelve lines, rated.

Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.

Property

Elevated
Gas torches, burnout and porcelain furnaces, alcohol lamps and methyl methacrylate monomer share small rooms with costly digital equipment.

Fire, explosion, water and weather damage to buildings, contents and stock.

Watch for
  • Furnaces running overnight unattended on combustible benches
  • Monomer and alcohol kept in open containers at benches
  • Oxygen and fuel gas cylinders unsecured or stored together
Controls that matter
  • Furnaces on non-combustible surfaces with clearance and timers
  • Flammable liquids limited to a day's supply outside a cabinet
  • Fixed gas piping with shut-off valves and flashback arrestors

Business interruption

Moderate
Cases can be outsourced to another lab within days, though scanners and mills take time to replace.

How long and how costly a shutdown is.

Watch for
  • A few dental groups providing most of the work
Controls that matter
  • Design files backed up off site and a reciprocal lab agreement

Premises liability

Low
A closed workshop fed by couriers and digital scans; the public has little reason to come in.

Injuries to customers and the public, on site or caused by operations elsewhere.

Watch for
  • Denture fittings, relines or repairs done for walk-in patients
Controls that matter
  • Separate clean patient room away from the workshop

Products and completed work

Elevated
Every appliance goes into a mouth: poor fit, fractures, undeclared alloys and allergic reactions bring remakes and occasional injury claims.

Harm caused by what the business sells, serves, makes, installs or repairs.

Watch for
  • Work outsourced offshore without disclosing origin or materials to the dentist
  • Nickel- or beryllium-containing alloys in crowns and frameworks
  • Implant components milled in-house to fit other makers' systems
Controls that matter
  • Material and lot records kept for every case
  • Written prescription from the dentist for each job
  • Approved materials only, with documentation passed to the dentist

Workers’ injury

Elevated
Grinding and blasting release silica and metal dust; monomer vapors, hot metal, sharp tools and fine repetitive work add up.

Injuries and illness to employees.

Watch for
  • Sandblasting or grinding without local extraction
  • Impressions handled without disinfection on arrival
  • Technicians working for hours at benches with poor posture support
Controls that matter
  • Extraction at every bench, with filters changed on schedule
  • Incoming cases disinfected before unpacking
  • Eye protection and heat-resistant gloves at casting stations

Commercial auto

Moderate
Small labs rely on couriers and scan files; larger ones keep a driver or two on local rounds.

Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.

Watch for
  • Part-time drivers using their own cars on tight schedules
Controls that matter
  • Driving record checks, or courier services in place of own drivers

Crime and theft

Moderate
Gold and other precious alloys, plus bench scrap, are compact and easy to remove.

Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.

Watch for
  • No weighing of alloy issued against metal returned
Controls that matter
  • Alloy locked in a safe and reconciled by weight

Inland marine and equipment

Moderate
Cases, models and impressions belonging to dentists move in and out by courier every day.

Property in transit, at job sites or in the insured’s care, and mobile equipment.

Watch for
  • High-value implant cases sent by uninsured post
Controls that matter
  • Transit cover for work in the lab's care and tracked delivery

Environmental

Moderate
Plaster sludge, pickling acids, monomer, electrolytes and metal dust arise in small quantities.

Pollution on or from the site or the work.

Watch for
  • Sinks without plaster traps, or acids poured to drain
Controls that matter
  • Plaster traps cleaned regularly and chemical waste collected by a licensed hauler

Cyber and data

Elevated
Intraoral scans, design files and patient names arrive from dentists online, and a ransomware attack stops scanning, milling and printing at once.

Data breaches, ransomware, system outages and attacks on connected equipment.

Watch for
  • Case management software and mills on one flat office network
  • Patient scans exchanged with dentists by unencrypted email
Controls that matter
  • Offline backups of design files and case records, tested regularly
  • Multi-factor sign-in for portals, email and remote design staff

Professional liability

Moderate
Work follows the dentist's prescription and clinical judgment; design, shade and material advice and any patient contact add modest exposure.

Loss or injury caused by advice, design, testing, care or another professional service.

Watch for
  • Denturists or technicians fitting appliances directly to patients
  • Remote design services sold to other labs and clinics
Controls that matter
  • Dentist approves the prescription and digital design before production
  • Patient care only by staff licensed for it where the law allows

Umbrella and excess

Moderate
Harm from a restoration is usually limited to one patient; a widespread alloy or material defect is the rare severe case.

How likely one liability event is to exhaust primary limits.

Watch for
  • One material lot used across many dentists' cases before a defect shows
Controls that matter
  • Material lot numbers recorded per case so affected patients can be traced
03 / Property picture

Construction, occupancy, protection, exposure.

What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.

Construction
Small units in older mixed-use or light industrial buildings, often upper floors or shared strips, with gas and compressed air piped to benches and frequent tenant alterations.
Occupancy
Gas torches, burnout and porcelain furnaces, acrylic monomer, alcohol lamps, resin printers and mills generating fine dust, with plaster and model stock throughout the workshop.
Protection
Monitored smoke detection, extinguishers at benches, furnaces on timers over non-combustible surfaces, flammable liquid cabinets, dust extraction, sprinklers where the building has them, and a safe for precious alloy.
Exposure
Shared walls and ceilings with restaurants, retailers and offices mean fire can travel both ways, and labs inside medical buildings depend on that building's protection.
04 / Checklist

What to ask and look for.

Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.

Before quoting: ask the broker or owner

Documents to request

On site: work performed

On site: premises and fire

On site: health and handling

On site: records and history

Refer or decline if you find

  • Furnaces left running overnight on wooden benches
  • Offshore outsourcing concealed from prescribing dentists
  • Blasting or grinding with no dust extraction
  • Beryllium alloys cast without specific controls
05 / Location

How UrbanStat data helps.

Labs often occupy older mixed-use buildings, where street-level units flood and benchtop furnaces, mills and gas lines shift in an earthquake. Precious alloy and compact digital equipment attract burglars.

FloodEarthquakeCrime
  • Crime scores at the address inform safe and alarm requirements for labs holding precious alloy and portable scanners.
  • Parcel and permit data give the construction date and permit history of older mixed-use buildings, a check on whether a lab's gas and electrical work was permitted.
  • The risk analysis API returns flood and earthquake scores in seconds, letting small-premium lab accounts be checked without slowing the quote.
Flood · Earthquake · Crime
06 / Public loss data · NAICS 339116

What the published numbers say.

Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.

Workers’ injury frequency

0.8 recordable injuries and illnesses per 100 full-time workers, below the private-industry average of 2.3.

Dental laboratories
0.8
All private industry
2.3

0.2 of these cases per 100 workers involved days away from work.

United States, 2024. Industry: Dental laboratories (NAICS 339116). Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.

Workplace deaths

4 fatal work injuries in 2024.

Manufacturing
2.4
All workers
3.3

Deaths per 100,000 full-time equivalent workers, for the industry sector as a whole.

United States, private industry, 2024. Industry: Medical Equipment and Supplies Manufacturing (NAICS 33911), the closest published group. Source: U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries; sector rates.

Most cited safety standards

16 citations from 2 inspections; 75% were classed serious, willful or repeat.

  • 1910.1030 Bloodborne pathogens
    11
  • 1910.1200 Hazard communication
    3
  • 1910.37 Maintenance, safeguards, and operational features for exit routes
    1
  • 1910.132 General requirements (personal protective equipment)
    1

Standards cited most often in this industry, by number of citations.

United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Dental Laboratories (NAICS 339116). Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).

Fire frequency

7,966 fires a year reported in industrial and manufacturing properties, causing about $810 million in direct property damage a year.

United States, 2020 to 2024, annual average. The group includes utility, defense, agriculture and mining properties. Source: National Fire Protection Association, Structure Fires in Industrial and Manufacturing Properties.

Toxic chemical releases

131 facilities reported toxic chemical releases totaling 3.4 million pounds on and off site.

  • Ethylene glycol
    2.6M
  • Methanol
    98,956
  • N-methyl-2-pyrrolidone
    95,774

Chemicals released in the largest amounts, in pounds. 80 of the facilities reported at least one chemical classed as a carcinogen.

United States, 2024. Industry: industry group 3391 (NAICS 3391), the closest published group. Covers facilities in listed industries with ten or more full-time employees that handle listed chemicals above set thresholds. Source: U.S. Environmental Protection Agency, Toxics Release Inventory basic data files.

Industry loss ratios by line2020 to 2024, the same table on every guide

Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.

Published lineClosest line in this guide20202021202220232024
FireProperty63.2%67.3%62.4%45.5%40.9%
Commercial multiple perilProperty and liability sold as a package61.2%60.2%59.4%61.2%54.4%
Inland marineInland marine and equipment64.5%49.4%47.1%44.1%44.0%
Other liabilityPremises liability, and most umbrella, professional (other than medical) and cyber cover65.1%58.8%61.0%63.7%71.2%
Products liabilityProducts and completed work48.2%52.2%46.0%57.5%60.3%
Workers’ compensationWorkers’ injury47.9%49.2%45.0%44.3%46.0%
Commercial auto liabilityCommercial auto68.3%66.5%71.9%76.8%77.6%
Commercial auto physical damageCommercial auto50.9%56.3%64.3%65.1%57.9%

United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.

Coverages to raise
Equipment breakdown
Mills, sintering furnaces and printers fail electrically or mechanically, stopping digital work while parts are shipped.
Valuable papers and records
Models, case records and design files belong to dentists and patients and are costly to recreate after a fire.
Product recall
A defective lot of zirconia, alloy or resin can force remakes across many dentists' cases.

NAICS and SIC codes for dental laboratories

SystemCodeIndustry
NAICS 2022, primary339116Dental Laboratories
SIC 1987, primary8072Dental Laboratories
Next step

See this risk on the map.

Book a 30-minute walkthrough tailored to your portfolio and perils of interest.

Request a Demo →