Cryptocurrency mining operationsNAICS 518210 · SIC 7374
Cryptocurrency miners run thousands of specialized computers that compete to validate transaction blocks for coin rewards, packed into warehouses, containers and immersion tanks at sites chosen for cheap power. Heat-dense rigs, thin redundancy and remote locations make fire and long outages likely, and income swings with coin prices.
NAICS 518210 Computing Infrastructure Providers, Data Processing, Web Hosting, and Related ServicesSIC 7374 Computer Processing and Data Preparation and Processing Services
Where losses come from.
- 01
Electrical fires in overloaded distribution, containers and immersion tanks packed with heat-dense mining machines
- 02
Power curtailment, utility failures or cooling breakdowns that halt mining for weeks at a remote site
- 03
Theft and fast obsolescence of machines whose resale value collapses when coin prices fall
- PropertyProperty: Severe, 5 of 5; sector average 2.7; all business types 2.9.
- Business interruptionBusiness interruption: High, 4 of 5; sector average 3.2; all business types 2.7.
- Premises liabilityPremises liability: Moderate, 2 of 5; sector average 2.3; all business types 2.7.
- Products and completed workProducts and completed work: Low, 1 of 5; sector average 1.9; all business types 2.6.
- Workers’ injuryWorkers’ injury: Elevated, 3 of 5; sector average 2.3; all business types 3.0.
- Commercial autoCommercial auto: Low, 1 of 5; sector average 2.2; all business types 2.5.
- Crime and theftCrime and theft: High, 4 of 5; sector average 2.5; all business types 2.2.
- Inland marine and equipmentInland marine and equipment: Elevated, 3 of 5; sector average 3.0; all business types 2.6.
- EnvironmentalEnvironmental: Elevated, 3 of 5; sector average 1.7; all business types 2.3.
- Cyber and dataCyber and data: Elevated, 3 of 5; sector average 3.4; all business types 2.7.
- Professional liabilityProfessional liability: Moderate, 2 of 5; sector average 2.1; all business types 2.0.
- Umbrella and excessUmbrella and excess: Moderate, 2 of 5; sector average 2.9; all business types 3.6.
- Each new machine generation makes older fleets uneconomic sooner, so insured values fall quickly and stated values drift above what replacement would cost.
- Immersion and hydro cooling allow denser, quieter sites but add tanks of fluid, pumps and leaks to an electrical fire risk.
- Miners are moving into hosting artificial intelligence computing, bringing tenants, uptime promises and costlier graphics processors to sites built for cheap, interruptible work.
Twelve lines, rated.
Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.
Property
SevereThousands of heat-dense machines fill unsprinklered metal buildings, containers or fluid tanks at remote sites where fire crews arrive late.
Fire, explosion, water and weather damage to buildings, contents and stock.
- Power distribution and cabling added faster than it was engineered
- Immersion fluid with a low flash point, or tanks without lids
- Machines valued at purchase price long after they lose value
- Thermal imaging of distribution panels, busbars and connectors on a schedule
- Fire separation between buildings or containers, with detection in each
- Agreed valuation basis tied to current secondary market prices
Business interruption
HighRevenue stops the moment power or cooling does, replacement machines can be scarce, and income value swings with coin prices.
How long and how costly a shutdown is.
- One site, one substation or one power contract carrying all output
- Curtailment and demand-response deals that make lost output hard to prove
- Interruption values set at a coin price far above today's
- Several sites on separate grids or power sources
- Interruption values reviewed against current coin price and network difficulty
- Spare transformers and power distribution units on site
Premises liability
ModerateSites are fenced and rarely visited, but constant fan noise and heat bring nuisance complaints and suits from neighbors.
Injuries to customers and the public, on site or caused by operations elsewhere.
- Air-cooled sites within earshot of homes
- Trespassers drawn to remote, lightly staffed compounds
- Noise studies, sound walls or immersion cooling near residences
- Perimeter fencing, lighting and monitored cameras
Products and completed work
LowMined coins are digital and cause no bodily harm; hosting other miners' machines is a service exposure.
Harm caused by what the business sells, serves, makes, installs or repairs.
- Used machines refurbished and resold to other miners
- Sale terms stating used machines are sold as-is
Workers’ injury
ElevatedTechnicians swap and repair machines in loud, hot halls, work near live high-voltage distribution and lift heavy units for long shifts.
Injuries and illness to employees.
- Constant fan noise above safe levels without hearing protection
- Lone technicians at remote sites far from emergency care
- Live electrical work on power distribution units
- Hearing protection, noise monitoring and hearing tests for site staff
- Lockout procedures and arc-flash rated gear for electrical work
- Check-in calls and heat stress rules for lone or summer work
Commercial auto
LowSmall crews drive pickups to remote sites; machines and containers arrive through freight carriers.
Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.
- Long rural drives and night call-outs to remote sites
- Driving policy and hired and non-owned auto cover for staff vehicles
Crime and theft
HighMining machines resell easily, remote compounds are lightly staffed, and wallet keys or pool accounts can be emptied in minutes.
Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.
- Payouts sent to online wallets controlled by one person
- Large prepayments for machines to unfamiliar sellers
- No serial-number inventory reconciled against machines in racks
- Multi-signature or offline storage for mined coins, with dual approval
- Monitored cameras, perimeter alarms and guard response at every site
- Verified sellers and escrow for machine purchases
Inland marine and equipment
ElevatedMachines arrive in high-value container shipments, and modular units move between sites or sit on well pads and hosts' land.
Property in transit, at job sites or in the insured’s care, and mobile equipment.
- Hosted clients' machines held without agreed values or contract terms
- Containers relocated by truck to remote well pads
- Transit cover for machine shipments from factory to rack
- Hosting agreements setting values and who insures client machines
Environmental
ElevatedImmersion fluids, transformer oil, generator fuel and piles of obsolete machines create spill and waste exposure, especially at off-grid gas-powered sites.
Pollution on or from the site or the work.
- Immersion tanks with no secondary containment
- Retired machines stockpiled outdoors awaiting disposal
- Diked tanks and spill kits for immersion fluid and transformer oil
- Licensed electronics recycler providing disposal certificates
Cyber and data
ElevatedMining pool accounts, wallets and machine firmware are attack targets, and hijacked machines can mine for someone else unnoticed.
Data breaches, ransomware, system outages and attacks on connected equipment.
- Machines left on default passwords or unpatched firmware
- Fleet management software reachable from the internet
- Mining network segmented, with machine management behind a secured gateway
- Multi-factor sign-in on pool, exchange and fleet accounts
Professional liability
ModerateHosting services for other miners promise uptime and power pricing, and outages or mismanaged machines bring client claims.
Loss or injury caused by advice, design, testing, care or another professional service.
- Hosting contracts with uptime guarantees and pass-through power prices
- Hosting terms excluding consequential loss and capping liability at fees
Umbrella and excess
ModerateFew outsiders are exposed at remote sites; a fire spreading to neighbors or grassland is the plausible large liability event.
How likely one liability event is to exhaust primary limits.
- Sites beside homes, farms or dry grassland
- Cleared, graveled buffers around buildings and containers
Construction, occupancy, protection, exposure.
What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.
- Construction
- Pre-engineered metal buildings, converted warehouses and shipping containers on gravel pads, often with open sides or fan walls, plus on-site substations and transformers.
- Occupancy
- Racks of mining machines running flat out around the clock, dense power distribution, immersion tanks of dielectric fluid, and at some sites gas generators fed from nearby wells.
- Protection
- Often minimal: detection, extinguishers and breaker coordination. Better sites add aspirating smoke detection, fire-separated containers, thermal monitoring, a water supply and a plan agreed with local responders.
- Exposure
- Remote rural or industrial sites near substations, power plants or gas fields, with long fire department response, dry vegetation nearby and neighbors who object to fan noise.
What to ask and look for.
Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.
Before quoting: ask the broker or owner
Documents to request
On site: power and electrical
On site: cooling and fire
On site: security and assets
On site: people and records
Refer or decline if you find
- Power distribution expanded without engineering or electrical inspection
- Containers or buildings packed together with no fire separation
- Machines insured at purchase price after coin prices fell
- Mined coins in online wallets controlled by one person
- Immersion tanks without containment, or filled with low flash point fluid
How UrbanStat data helps.
Many sites sit in open grassland where wildfire and tornadoes reach metal buildings and containers, high winds and hail damage fan walls and transformers, and lightly staffed compounds draw thieves.
- Wildfire and tornado scores at the address show whether a remote compound of metal buildings and containers faces grass fire or violent wind before limits are set.
- Crime scores at the address inform security conditions for lightly staffed sites holding thousands of resellable mining machines.
- Referral areas drawn on the map for wildfire-prone grassland route new mining sites there to an underwriter automatically, at quote and again at renewal.
What the published numbers say.
Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.
0.3 recordable injuries and illnesses per 100 full-time workers, below the private-industry average of 2.3.
0.1 of these cases per 100 workers involved days away from work.
United States, 2024. Industry: Data processing, hosting, and related services (NAICS 518), the closest published group. Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.
25 citations from 8 inspections; 72% were classed serious, willful or repeat.
- 1910.335 Safeguards for personnel protection3
- 1910.178 Powered industrial trucks2
- 1910.332 Training (electrical)2
- 1910.157 Portable fire extinguishers2
- 1910.134 Respiratory protection2
Standards cited most often in this industry, by number of citations.
United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Computing Infrastructure Providers, Data Processing, Web Hosting, and Related Services (NAICS 518210). Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).
7,966 fires a year reported in industrial and manufacturing properties, causing about $810 million in direct property damage a year.
United States, 2020 to 2024, annual average. The group includes utility, defense, agriculture and mining properties. Source: National Fire Protection Association, Structure Fires in Industrial and Manufacturing Properties.
Industry loss ratios by line2020 to 2024, the same table on every guide
Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.
| Published line | Closest line in this guide | 2020 | 2021 | 2022 | 2023 | 2024 |
|---|---|---|---|---|---|---|
| Fire | Property | 63.2% | 67.3% | 62.4% | 45.5% | 40.9% |
| Commercial multiple peril | Property and liability sold as a package | 61.2% | 60.2% | 59.4% | 61.2% | 54.4% |
| Inland marine | Inland marine and equipment | 64.5% | 49.4% | 47.1% | 44.1% | 44.0% |
| Other liability | Premises liability, and most umbrella, professional (other than medical) and cyber cover | 65.1% | 58.8% | 61.0% | 63.7% | 71.2% |
| Products liability | Products and completed work | 48.2% | 52.2% | 46.0% | 57.5% | 60.3% |
| Workers’ compensation | Workers’ injury | 47.9% | 49.2% | 45.0% | 44.3% | 46.0% |
| Commercial auto liability | Commercial auto | 68.3% | 66.5% | 71.9% | 76.8% | 77.6% |
| Commercial auto physical damage | Commercial auto | 50.9% | 56.3% | 64.3% | 65.1% | 57.9% |
United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.
- Equipment breakdown
- Transformers, power distribution units and cooling plant fail without fire and stop all mining until replaced.
- Utility service interruption
- A substation or line failure off site cuts power though the property itself is undamaged.
- Digital asset theft and custody
- Standard crime forms exclude cryptocurrency, so stolen coins need specialized custody or theft cover.
- Transit
- New machines ship in costly container loads, and title often passes before they arrive on site.
- Directors and officers
- Publicly traded miners face shareholder suits over volatile results, financing and disclosures about power deals.
See this risk on the map.
Book a 30-minute walkthrough tailored to your portfolio and perils of interest.