Thermal power plantsNAICS 221112 · SIC 4911

Thermal power plants burn gas, coal, oil or biomass, or tap geothermal or nuclear heat, to raise steam or drive gas turbines that spin large generators. Losses center on turbine, boiler and generator breakdown, fuel and transformer fires, dust explosions, and outages that last months while one-off parts are made.

NAICS 221112 Fossil Fuel Electric Power GenerationSIC 4911 Electric ServicesNAICS 221117 Biomass Electric Power GenerationNAICS 221116 Geothermal Electric Power Generation+1 more code

Utilities · Updated November 2026

01 / Loss drivers

Where losses come from.

  1. 01

    Gas turbine, steam turbine and generator failures that take months to repair and halt output

  2. 02

    Fires and explosions in fuel handling, coal or biomass dust, lube oil systems and transformers

  3. 03

    Boiler tube leaks, furnace explosions and steam releases that injure workers and stop units

How it comparesEach line’s rating against the average for its NAICS sector, Utilities (10 business types), and for all 747.
  1. PropertyProperty: Severe, 5 of 5; sector average 4.0; all business types 2.9.
  2. Business interruptionBusiness interruption: Severe, 5 of 5; sector average 3.7; all business types 2.7.
  3. Premises liabilityPremises liability: Elevated, 3 of 5; sector average 3.7; all business types 2.7.
  4. Products and completed workProducts and completed work: Moderate, 2 of 5; sector average 2.2; all business types 2.6.
  5. Workers’ injuryWorkers’ injury: Elevated, 3 of 5; sector average 3.2; all business types 3.0.
  6. Commercial autoCommercial auto: Moderate, 2 of 5; sector average 2.2; all business types 2.5.
  7. Crime and theftCrime and theft: Moderate, 2 of 5; sector average 1.7; all business types 2.2.
  8. Inland marine and equipmentInland marine and equipment: Elevated, 3 of 5; sector average 2.8; all business types 2.6.
  9. EnvironmentalEnvironmental: High, 4 of 5; sector average 3.2; all business types 2.3.
  10. Cyber and dataCyber and data: Elevated, 3 of 5; sector average 3.3; all business types 2.7.
  11. Professional liabilityProfessional liability: Low, 1 of 5; sector average 1.5; all business types 2.0.
  12. Umbrella and excessUmbrella and excess: High, 4 of 5; sector average 4.2; all business types 3.6.
What’s changing
  • Gas plants now cycle on and off to balance wind and solar output, wearing turbines and boilers faster than the baseload duty they were built for.
  • Coal units are closing or converting to gas and biomass, leaving aging plants run on tighter budgets with new fuel-handling hazards.
  • Some plants are adding hydrogen blending and carbon capture, which bring new fire, explosion and chemical exposures onto the site.
02 / Line by line

Twelve lines, rated.

Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.

Property

Severe
Turbine lube oil, hydrogen-cooled generators, coal and biomass dust and oil-filled transformers can each produce a total loss of the unit.

Fire, explosion, water and weather damage to buildings, contents and stock.

Watch for
  • Coal or biomass conveyors and silos without dust control or spark detection
  • Transformers close together or near the turbine hall without fire walls
  • Gas turbines started and stopped daily, wearing hot parts faster
Controls that matter
  • Sprinklers or water spray on turbine bearings and lube oil skids
  • Fire walls, oil pits and deluge on large transformers
  • Spark detection, venting and isolation on fuel handling and silos

Business interruption

Severe
One turbine, boiler or step-up transformer can carry the whole plant, and replacements are built to order over many months.

How long and how costly a shutdown is.

Watch for
  • Single-shaft units with no fleet spare rotor or transformer
  • Capacity contracts with heavy penalties for unavailability
  • Fuel delivered by one pipeline, rail line or supplier
Controls that matter
  • Spare transformers and turbine parts pooled across the owner's fleet
  • Overhauls done at the intervals the turbine maker sets

Premises liability

Elevated
Large contractor crews during outages bring injury and action-over claims, and an explosion or ammonia release can reach neighbors.

Injuries to customers and the public, on site or caused by operations elsewhere.

Watch for
  • Coal or ash piles and cooling towers close to homes
  • Large contractor crews on site during planned outages
Controls that matter
  • Contractor induction, work permits and supervision during outages
  • Dust suppression on stockpiles, conveyors and haul roads

Products and completed work

Moderate
Power goes to the grid, but steam or heat sold to an industrial neighbor makes an outage the plant's liability.

Harm caused by what the business sells, serves, makes, installs or repairs.

Watch for
  • Steam, heat or power supplied directly to a factory or campus
Controls that matter
  • Supply contracts that cap liability for interruption and quality

Workers’ injury

Elevated
Operators and maintenance staff face high-pressure steam, hot surfaces, confined spaces in boilers and ducts, and high voltage.

Injuries and illness to employees.

Watch for
  • Boiler and duct entries without gas testing and a standby attendant
  • Coal conveyors with missing guards or pull cords
  • Arc-flash exposure in switchgear rooms during live work
Controls that matter
  • Permit system covering confined space, hot work and lockout
  • Arc-flash studies, labeled switchgear and rated protective clothing

Commercial auto

Moderate
Staff drive site vehicles and commute to shifts; fuel and ash usually move by contracted rail, barge or truck.

Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.

Watch for
  • Plant-owned trucks hauling ash or fuel on public roads
Controls that matter
  • Contract haulers carrying their own insurance under written agreements

Crime and theft

Moderate
Copper, tools and spare parts draw theft, and large fuel and contractor invoices invite payment fraud.

Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.

Watch for
  • Changes to supplier bank details accepted by email
Controls that matter
  • Call-back checks on any change to payment details

Inland marine and equipment

Elevated
Rotors, blades and transformers travel to repair shops and back, and dozers and stackers move coal and biomass on site.

Property in transit, at job sites or in the insured’s care, and mobile equipment.

Watch for
  • Major components shipped for repair without transit cover in place
  • Mobile fuel-handling equipment working on coal or wood piles
Controls that matter
  • Transit cover for components sent away for overhaul
  • Fire suppression on dozers, loaders and stackers in fuel yards

Environmental

High
Fuel oil, ammonia for emissions control, ash ponds, heated cooling water and asbestos insulation in older units create spill, discharge and exposure claims.

Pollution on or from the site or the work.

Watch for
  • Unlined ash ponds, or ash dams showing seepage
  • Bulk ammonia near the fence line, or hydrogen sulfide from geothermal wells
  • Asbestos insulation on older boilers, turbines and piping disturbed during outages
Controls that matter
  • Lined ash storage with groundwater monitoring wells
  • Diked fuel and chemical tanks with leak detection

Cyber and data

Elevated
Distributed control systems run the units and link to grid dispatch; an intrusion can trip the plant or damage machinery.

Data breaches, ransomware, system outages and attacks on connected equipment.

Watch for
  • Control network bridged to the office network or vendor links
  • Old control systems running unsupported software
Controls that matter
  • Separated control network with monitored, session-based vendor access
  • Offline backups of control system configurations

Professional liability

Low
Generators sell power, not advice; engineering errors fall on designers and service contractors.

Loss or injury caused by advice, design, testing, care or another professional service.

Watch for
  • Operation and maintenance services sold to other plant owners
Controls that matter
  • Written scope and liability caps in any operating contract for another owner

Umbrella and excess

High
A boiler or gas explosion, an ash dam breach or an ammonia release can harm many workers and neighbors at once.

How likely one liability event is to exhaust primary limits.

Watch for
  • Homes or public roads close to ammonia storage or ash ponds
Controls that matter
  • Emergency plans shared with local responders and exercised with neighbors
03 / Property picture

Construction, occupancy, protection, exposure.

What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.

Construction
Tall steel-framed turbine halls and boiler houses on heavy concrete foundations, with cooling towers, tank farms, fuel yards and switchyards, often decades old with additions and fuel conversions.
Occupancy
Fuel burned at high temperature and pressure, turbine lube oil and generator hydrogen beside hot casings, combustible coal or wood dust, large oil-filled transformers, and cooling tower fill that burns when dry.
Protection
A fire water loop with dedicated pumps, sprinklers and deluge on turbines and transformers, dust explosion protection on fuel handling, burner management systems and a trained on-site response team.
Exposure
Plants sit on rivers, lakes or coasts for cooling water, which brings flood and surge, and often beside rail lines, pipelines and industrial neighbors that share the risk.
04 / Checklist

What to ask and look for.

Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.

Before quoting: ask the broker or owner

Documents to request

On site: turbines and boilers

On site: fuel and fire protection

On site: operations and people

On site: site and surroundings

Refer or decline if you find

  • Turbine overhauls deferred well past the manufacturer's recommended intervals
  • Coal or biomass dust built up on beams, ledges and conveyors
  • Large transformers without fire walls, oil containment or deluge
  • Fire pumps or sprinklers impaired for long periods with no compensating measures
  • Ash pond or dam with seepage, cracking or no engineering inspection
05 / Location

How UrbanStat data helps.

Cooling-water sites on rivers and coasts face flood and storm surge into switchyards and pump houses. Earthquakes upset turbine alignment and crack tanks, and drought or heat waves limit cooling water and output.

FloodStorm surgeHurricaneEarthquakeTornado
  • Flood and storm surge scores at the plant address show whether switchyards, cooling-water pumps and control rooms sit below likely water levels.
  • Accumulation views show how much insured value sits around one plant, including neighboring industrial sites, with alerts when a set threshold is passed.
  • A risk analysis API returns peril scores in seconds, so checks on every plant in a large generating fleet run inside the quoting workflow.
Flood · Storm surge · Hurricane · Earthquake
06 / Public loss data · NAICS 221112

What the published numbers say.

Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.

Workers’ injury frequency

2.3 recordable injuries and illnesses per 100 full-time workers, close to the private-industry average of 2.3.

Fossil fuel electric power generation
2.3
All private industry
2.3

1.1 of these cases per 100 workers involved days away from work.

United States, 2024. Industry: Fossil fuel electric power generation (NAICS 221112). Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.

Workplace deaths

5 fatal work injuries in 2024.

United States, private industry, 2024. Industry: Electric Power Generation (NAICS 22111), the closest published group. Source: U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries.

Most cited safety standards

16 citations from 6 inspections; 94% were classed serious, willful or repeat.

  • 1910.269 Electric power generation, transmission, and distribution
    5
  • 1910.212 General requirements for all machines
    2
  • 1910.141 Sanitation
    2
  • 1910.28 Duty to have fall protection and falling object protection
    1
  • 1910.146 Permit-required confined spaces
    1

Standards cited most often in this industry, by number of citations.

United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Fossil Fuel Electric Power Generation (NAICS 221112). Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).

Fire frequency

7,966 fires a year reported in industrial and manufacturing properties, causing about $810 million in direct property damage a year.

United States, 2020 to 2024, annual average. The group includes utility, defense, agriculture and mining properties. Source: National Fire Protection Association, Structure Fires in Industrial and Manufacturing Properties.

Toxic chemical releases

367 facilities reported toxic chemical releases totaling 180.7 million pounds on and off site.

  • Barium and barium compounds
    59.4M
  • Sulfuric acid
    25.3M
  • Barium compounds
    24M

Chemicals released in the largest amounts, in pounds. 292 of the facilities reported at least one chemical classed as a carcinogen.

United States, 2024. Industry: Fossil Fuel Electric Power Generation (NAICS 221112). Covers facilities in listed industries with ten or more full-time employees that handle listed chemicals above set thresholds. Source: U.S. Environmental Protection Agency, Toxics Release Inventory basic data files.

Industry loss ratios by line2020 to 2024, the same table on every guide

Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.

Published lineClosest line in this guide20202021202220232024
FireProperty63.2%67.3%62.4%45.5%40.9%
Commercial multiple perilProperty and liability sold as a package61.2%60.2%59.4%61.2%54.4%
Inland marineInland marine and equipment64.5%49.4%47.1%44.1%44.0%
Other liabilityPremises liability, and most umbrella, professional (other than medical) and cyber cover65.1%58.8%61.0%63.7%71.2%
Products liabilityProducts and completed work48.2%52.2%46.0%57.5%60.3%
Workers’ compensationWorkers’ injury47.9%49.2%45.0%44.3%46.0%
Commercial auto liabilityCommercial auto68.3%66.5%71.9%76.8%77.6%
Commercial auto physical damageCommercial auto50.9%56.3%64.3%65.1%57.9%

United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.

Coverages to raise
Equipment breakdown
Turbine, generator and transformer failures without fire are the most frequent large losses at these plants.
Nuclear liability and property
Nuclear sites need separate nuclear liability and property cover through specialist pools, which ordinary policies exclude.
Off-premises utility and fuel supply
A pipeline, rail or grid outage stops generation even when the plant itself is undamaged.
Builders risk
Fuel conversions and new emissions equipment bring large construction projects onto sites that keep operating.

NAICS and SIC codes for thermal power plants

SystemCodeIndustry
NAICS 2022, primary221112Fossil Fuel Electric Power Generation
NAICS 2022221117Biomass Electric Power Generation
NAICS 2022221116Geothermal Electric Power Generation
NAICS 2022221113Nuclear Electric Power Generation
SIC 1987, primary4911Electric Services
Next step

See this risk on the map.

Book a 30-minute walkthrough tailored to your portfolio and perils of interest.

Request a Demo →