Wind farmsNAICS 221115 · SIC 4911

Wind farms own and run fleets of utility-scale turbines, collection cables and a substation, selling power to the grid under long contracts. Losses come from blade, gearbox, bearing and generator failures that need large cranes to fix, lightning and nacelle fires nobody can fight, and serial defects across one turbine model.

NAICS 221115 Wind Electric Power GenerationSIC 4911 Electric Services

Utilities · Updated November 2026

01 / Loss drivers

Where losses come from.

  1. 01

    Gearbox, main bearing, generator and blade failures that idle turbines for months awaiting cranes and parts

  2. 02

    Lightning strikes and nacelle fires high above the ground that burn out turbines beyond reach

  3. 03

    Serial defects in one turbine model or blade batch that force repairs across the whole fleet

How it comparesEach line’s rating against the average for its NAICS sector, Utilities (10 business types), and for all 747.
  1. PropertyProperty: Severe, 5 of 5; sector average 4.0; all business types 2.9.
  2. Business interruptionBusiness interruption: High, 4 of 5; sector average 3.7; all business types 2.7.
  3. Premises liabilityPremises liability: Elevated, 3 of 5; sector average 3.7; all business types 2.7.
  4. Products and completed workProducts and completed work: Low, 1 of 5; sector average 2.2; all business types 2.6.
  5. Workers’ injuryWorkers’ injury: High, 4 of 5; sector average 3.2; all business types 3.0.
  6. Commercial autoCommercial auto: Moderate, 2 of 5; sector average 2.2; all business types 2.5.
  7. Crime and theftCrime and theft: Moderate, 2 of 5; sector average 1.7; all business types 2.2.
  8. Inland marine and equipmentInland marine and equipment: Elevated, 3 of 5; sector average 2.8; all business types 2.6.
  9. EnvironmentalEnvironmental: Moderate, 2 of 5; sector average 3.2; all business types 2.3.
  10. Cyber and dataCyber and data: Elevated, 3 of 5; sector average 3.3; all business types 2.7.
  11. Professional liabilityProfessional liability: Low, 1 of 5; sector average 1.5; all business types 2.0.
  12. Umbrella and excessUmbrella and excess: Elevated, 3 of 5; sector average 4.2; all business types 3.6.
What’s changing
  • Turbines keep getting taller with longer blades, so each failure costs more, needs bigger cranes and takes longer to repair.
  • Repowering swaps early turbines for fewer, larger machines on the same land, mixing new designs whose failure patterns have short service records.
  • Drones, vibration sensors and remote monitoring catch blade and drivetrain damage earlier, but connect every turbine to networks that attackers can probe.
02 / Line by line

Twelve lines, rated.

Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.

Property

Severe
Blade, gearbox and bearing failures recur across fleets, lightning strikes every season, and a nacelle fire burns the turbine out completely.

Fire, explosion, water and weather damage to buildings, contents and stock.

Watch for
  • Turbine models with known blade, bearing or gearbox weaknesses
  • Older turbines with no nacelle fire detection or suppression
  • Array and export cable faults, which offshore need specialist vessels to repair
Controls that matter
  • Drivetrain vibration and oil monitoring, with alarms acted on promptly
  • Automatic suppression in nacelles and converter cabinets
  • Lightning protection tested and blades inspected by drone on a schedule

Business interruption

High
Repairs wait for large cranes, weather windows and parts from one manufacturer, and a main transformer failure stops the whole farm.

How long and how costly a shutdown is.

Watch for
  • One main transformer or export cable carrying all output
  • Turbine model out of production, with scarce spare parts
  • Remote or offshore sites where cranes and vessels are booked far ahead
Controls that matter
  • Spare transformer held on site or shared across the owner's farms
  • Strategic spares for gearboxes, bearings and blades under the service contract

Premises liability

Elevated
Burning debris from nacelle fires, thrown ice and broken blades can reach roads, crops, grassland and neighbors' land.

Injuries to customers and the public, on site or caused by operations elsewhere.

Watch for
  • Turbines within falling distance of roads, trails or homes
  • Dry grassland or ripe crops beneath turbines in fire season
  • Public access to towers and tracks on leased farmland
Controls that matter
  • Ice detection that stops turbines, with warning signs on nearby routes
  • Firebreaks and cleared ground around each tower base

Products and completed work

Low
Power is sold at the substation to the grid or a single buyer; nothing is sold to the public.

Harm caused by what the business sells, serves, makes, installs or repairs.

Watch for
  • Power supplied directly to a nearby factory or community under its own contract
Controls that matter
  • Supply terms that limit liability for outages and voltage problems

Workers’ injury

High
Technicians climb tall towers and work inside cramped nacelles and hubs on live electrical gear, far from rescue services.

Injuries and illness to employees.

Watch for
  • Climbs without continuous fall arrest or a climb-assist system
  • Lone working, or two-person crews with no rescue plan
  • Rotor not locked or power not isolated before nacelle work
Controls that matter
  • Service lifts or climb assist fitted in every tower
  • Rescue and descent kit in each nacelle, with crews trained to use it
  • Lockout of rotor and electrical systems before every entry

Commercial auto

Moderate
Technicians drive pickups over gravel access roads and rural highways daily; heavy components move by specialist haulers.

Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.

Watch for
  • Long daily drives between turbines and distant sites in winter conditions
Controls that matter
  • Driving record checks and telematics on service vehicles

Crime and theft

Moderate
Copper cable, tools and spare parts sit in remote laydown yards and substations that few people pass.

Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.

Watch for
  • Unfenced laydown yards holding cable drums and spare parts
Controls that matter
  • Fenced, camera-monitored yards and substations with alarm response

Inland marine and equipment

Elevated
Replacement blades, gearboxes and generators travel long distances as oversized loads, and spares sit in storage away from the turbines.

Property in transit, at job sites or in the insured’s care, and mobile equipment.

Watch for
  • Major component exchanges with parts shipped between distant sites
  • Spare blades stored outdoors on rough, unprotected ground
Controls that matter
  • Transit cover for components moved for repair or exchange
  • Spares stored on engineered stands inside fenced yards

Environmental

Moderate
Gearbox, hydraulic and transformer oils are the main pollutants, with leaks onto farmland and composite blade waste to dispose of.

Pollution on or from the site or the work.

Watch for
  • Oil leaks running down towers onto soil or into drainage
  • Burned composite debris scattered over cropland after a nacelle fire
Controls that matter
  • Leak checks at each service visit and containment under substation transformers

Cyber and data

Elevated
Every turbine is controlled and monitored remotely; an intrusion through the control system or a vendor link can stop the farm.

Data breaches, ransomware, system outages and attacks on connected equipment.

Watch for
  • Manufacturer remote access left open with shared credentials
  • Control network linked directly to office systems or the internet
Controls that matter
  • Control network separated from business systems and monitored
  • Vendor access granted per session, with logging and multi-factor login

Professional liability

Low
The owner sells power, not advice; design errors belong to manufacturers, engineers and contractors.

Loss or injury caused by advice, design, testing, care or another professional service.

Watch for
  • Asset management or operations services sold to other wind farm owners
Controls that matter
  • Services for other owners run under separate contracts with capped liability

Umbrella and excess

Elevated
A wildfire spreading from a burning turbine, or a blade or ice striking a vehicle, can produce claims beyond primary limits.

How likely one liability event is to exhaust primary limits.

Watch for
  • Turbines close to homes, highways or dry brush
Controls that matter
  • Setbacks, ice shutdown and firebreaks documented for each turbine
03 / Property picture

Construction, occupancy, protection, exposure.

What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.

Construction
Tubular steel or concrete towers on reinforced foundations carry nacelles of steel and glass-fiber composite, with a substation, control building and spares store on gravel pads across leased land or offshore.
Occupancy
Each nacelle packs gearbox and hydraulic oil, a generator, power electronics and often a transformer into a combustible shell high above the ground, running unattended in all weather.
Protection
Smoke detection and automatic suppression in nacelles and converter cabinets, lightning receptors and grounding tested regularly, drivetrain condition monitoring, and remote shutdown from a staffed control room.
Exposure
Open, remote sites take lightning, icing and extreme gusts; a nacelle fire drops burning debris onto crops and brush, and fire crews have no way to reach the height.
04 / Checklist

What to ask and look for.

Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.

Before quoting: ask the broker or owner

Documents to request

On site: turbines and drivetrain

On site: substation and control

On site: work at height

On site: records and history

Refer or decline if you find

  • Turbine model with known blade or gearbox defects and no remediation plan
  • Older turbines with no fire detection or suppression in the nacelle
  • Single main transformer with no spare and a long replacement lead time
  • Service contract lapsed, with maintenance left to unvetted contractors
  • Turbines near homes, roads or dry brush with past ice throw or fires
05 / Location

How UrbanStat data helps.

Turbines are built for wind but not for tornadoes or gusts beyond their survival speed. Hail scars blade edges, grassland fire threatens cabling and substations, and coastal or offshore farms add hurricane exposure.

TornadoHailWindWildfireHurricane
  • Tornado, hail and wildfire scores at each turbine pad and the substation show which parts of a spread-out farm carry the most weather exposure.
  • Street-by-street portfolio views show how much insured turbine value sits in one wind corridor, with alerts when the accumulation passes a set threshold.
  • Live hurricane tracks and wildfire perimeters show which insured turbines and substations are in the path, helping plan inspections and crane access afterwards.
Tornado · Hail · Wind · Wildfire
06 / Public loss data · NAICS 221115

What the published numbers say.

Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.

Workers’ injury frequency

1.7 recordable injuries and illnesses per 100 full-time workers, below the private-industry average of 2.3.

Electric power generation
1.7
All private industry
2.3

0.9 of these cases per 100 workers involved days away from work.

United States, 2024. Industry: Electric power generation (NAICS 22111), the closest published group. Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.

Workplace deaths

3 fatal work injuries in 2024.

United States, private industry, 2024. Industry: Wind Electric Power Generation (NAICS 221115). Source: U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries.

Most cited safety standards

317 citations from 146 inspections; 64% were classed serious, willful or repeat.

  • 1910.269 Electric power generation, transmission, and distribution
    41
  • 1926.501 Duty to have fall protection
    26
  • 1904.29 Forms
    10
  • 1910.303 General (electrical)
    9
  • 1910.132 General requirements (personal protective equipment)
    9

Standards cited most often in this industry, by number of citations.

United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Electric Power Generation, Transmission and Distribution (NAICS 2211), the closest published group. Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).

Fire frequency

7,966 fires a year reported in industrial and manufacturing properties, causing about $810 million in direct property damage a year.

United States, 2020 to 2024, annual average. The group includes utility, defense, agriculture and mining properties. Source: National Fire Protection Association, Structure Fires in Industrial and Manufacturing Properties.

Toxic chemical releases

395 facilities reported toxic chemical releases totaling 191.1 million pounds on and off site.

  • Barium and barium compounds
    60.3M
  • Barium compounds
    27.8M
  • Sulfuric acid
    25.8M

Chemicals released in the largest amounts, in pounds. 311 of the facilities reported at least one chemical classed as a carcinogen.

United States, 2024. Industry: industry group 2211 (NAICS 2211), the closest published group. Covers facilities in listed industries with ten or more full-time employees that handle listed chemicals above set thresholds. Source: U.S. Environmental Protection Agency, Toxics Release Inventory basic data files.

Industry loss ratios by line2020 to 2024, the same table on every guide

Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.

Published lineClosest line in this guide20202021202220232024
FireProperty63.2%67.3%62.4%45.5%40.9%
Commercial multiple perilProperty and liability sold as a package61.2%60.2%59.4%61.2%54.4%
Inland marineInland marine and equipment64.5%49.4%47.1%44.1%44.0%
Other liabilityPremises liability, and most umbrella, professional (other than medical) and cyber cover65.1%58.8%61.0%63.7%71.2%
Products liabilityProducts and completed work48.2%52.2%46.0%57.5%60.3%
Workers’ compensationWorkers’ injury47.9%49.2%45.0%44.3%46.0%
Commercial auto liabilityCommercial auto68.3%66.5%71.9%76.8%77.6%
Commercial auto physical damageCommercial auto50.9%56.3%64.3%65.1%57.9%

United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.

Coverages to raise
Equipment breakdown
Gearbox, bearing and generator failures without any fire are the most frequent losses and need machinery cover.
Serial loss terms
A repeating defect across one turbine model can trigger many claims; how the policy treats them decides the recovery.
Utility and grid interruption
A fault on the grid operator's line stops all sales even when every turbine is working.
Builders risk
Repowering old turbines or adding new phases puts construction work and new components on an operating site.

NAICS and SIC codes for wind farms

SystemCodeIndustry
NAICS 2022, primary221115Wind Electric Power Generation
SIC 1987, primary4911Electric Services
Next step

See this risk on the map.

Book a 30-minute walkthrough tailored to your portfolio and perils of interest.