Radon mitigation contractorsNAICS 238990 · SIC 1799
Radon mitigation contractors lower indoor radon by drilling through the slab, sealing entry points and installing a fan and vent pipe that draw soil gas from under the building to above the roof. A system that underperforms or disturbs the house's air balance leaves occupants exposed for years.
NAICS 238990 All Other Specialty Trade ContractorsSIC 1799 Special Trade Contractors, NECNAICS 562910 Remediation Services
Where losses come from.
- 01
Systems that fail to bring radon down, discovered years later
- 02
Backdrafting of furnaces and water heaters, pulling carbon monoxide indoors
- 03
Falls, crawl-space injuries and dust exposure while drilling and routing pipe
- PropertyProperty: Low, 1 of 5; sector average 2.2; all business types 2.9.
- Business interruptionBusiness interruption: Low, 1 of 5; sector average 1.8; all business types 2.7.
- Premises liabilityPremises liability: Moderate, 2 of 5; sector average 3.5; all business types 2.7.
- Products and completed workProducts and completed work: High, 4 of 5; sector average 3.8; all business types 2.6.
- Workers’ injuryWorkers’ injury: Elevated, 3 of 5; sector average 3.8; all business types 3.0.
- Commercial autoCommercial auto: Elevated, 3 of 5; sector average 3.1; all business types 2.5.
- Crime and theftCrime and theft: Low, 1 of 5; sector average 1.7; all business types 2.2.
- Inland marine and equipmentInland marine and equipment: Moderate, 2 of 5; sector average 3.2; all business types 2.6.
- EnvironmentalEnvironmental: Elevated, 3 of 5; sector average 2.5; all business types 2.3.
- Cyber and dataCyber and data: Moderate, 2 of 5; sector average 2.0; all business types 2.7.
- Professional liabilityProfessional liability: Moderate, 2 of 5; sector average 2.3; all business types 2.0.
- Umbrella and excessUmbrella and excess: Elevated, 3 of 5; sector average 4.0; all business types 3.6.
- Building codes increasingly require passive radon pipes in new homes, so mitigators often activate builder systems they neither designed nor installed.
- Low-cost continuous monitors give owners daily readings, so failing fans and rising levels are noticed sooner, turning hidden long-term failures into earlier callbacks.
- Heat pumps and electric water heaters replacing gas appliances reduce backdraft risk, while tighter, energy-efficient homes make pressure balance harder to get right.
Twelve lines, rated.
Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.
Property
LowA small office or home base with a van stock of pipe, fans and sealant.
Fire, explosion, water and weather damage to buildings, contents and stock.
- Solvent cements and foam sealants stored in bulk
- Stock kept to van quantities, with flammables in a cabinet
Business interruption
LowTools and parts are off-the-shelf and jobs take a day; interruption is brief.
How long and how costly a shutdown is.
- License or certification held by one individual only
- More than one certified person on staff
Premises liability
ModerateShort jobs in occupied homes involve core drilling slabs, cutting through roofs and walls, and wiring fans.
Injuries to customers and the public, on site or caused by operations elsewhere.
- Core drilling through slabs with radiant heating or buried lines
- Roof and siding penetrations left poorly flashed
- Slab scanned or drawings checked before drilling
- Penetrations flashed and sealed, with photos kept
Products and completed work
HighThe installed system is a health device: if it fails silently, occupants breathe a carcinogen for years.
Harm caused by what the business sells, serves, makes, installs or repairs.
- No post-installation test, or testing done by the installer alone
- Exhaust discharged below the roofline or near windows
- Fans mounted in basements or living space, where leaks re-enter the house
- Independent follow-up test after every installation
- System pressure gauge or alarm the owner can read
- Combustion appliance backdraft test before leaving the job
Workers’ injury
ElevatedTechnicians work on ladders and roofs, in crawl spaces, and breathe concrete dust and radon while drilling.
Injuries and illness to employees.
- Lone workers in crawl spaces and attics
- Dry core drilling of slabs
- Technicians' cumulative radon exposure never tracked
- Wet drilling or vacuum dust capture
- Ladder tie-off and roof fall protection
- Exposure records and ventilation while working in high-radon basements
Commercial auto
ElevatedService vans travel to one or two homes a day across a wide territory.
Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.
- Wide rural territories with long daily mileage
- Driving record checks and van telematics
Crime and theft
LowNo stock of value beyond fans and tools, and payments are by card or transfer.
Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.
- Tools and monitors left in vans overnight
- Vans locked and alarmed, with monitors taken indoors
Inland marine and equipment
ModerateCore drills, vacuums, test monitors and fan stock ride in the vans.
Property in transit, at job sites or in the insured’s care, and mobile equipment.
- Continuous radon monitors left at customers' homes
- Scheduled list of monitors and tools with serial numbers
Environmental
ElevatedRadon is itself a pollutant, and crews drill and seal in basements with asbestos tile, mold and chemical vapors.
Pollution on or from the site or the work.
- Liability policy whose pollution exclusion removes radon claims
- Work extended to chemical vapor intrusion on contaminated sites
- Old floor tile or pipe wrap disturbed during drilling
- Pollution cover that names radon and the contractor's work
- Suspect materials tested or avoided before drilling
Cyber and data
ModerateCustomer addresses, test results and photos sit in scheduling software, and connected monitors report readings through online accounts.
Data breaches, ransomware, system outages and attacks on connected equipment.
- Monitor and fan alarm data held in cloud accounts the firm manages
- Payment links and invoices sent by email to real estate agents
- Multifactor login on scheduling, monitoring and accounting systems
- Payment changes confirmed by phone with a known contact
Professional liability
ModerateDiagnostic testing and system design are advice that buyers rely on in home sales, though the installed system carries most claims.
Loss or injury caused by advice, design, testing, care or another professional service.
- The firm tests the homes it then mitigates during real estate deals
- Vapor intrusion designs for commercial or contaminated sites
- Post-mitigation tests by an independent tester or a documented protocol
- Chemical vapor work designed by a licensed professional
Umbrella and excess
ElevatedA backdrafting furnace that poisons a family, or a pattern of failed systems across a builder's subdivision, can exceed primary limits.
How likely one liability event is to exhaust primary limits.
- Volume contracts with home builders for whole subdivisions
- Systems in schools, daycares or apartment buildings
- Combustion backdraft testing recorded on every job
- Builder contracts reviewed for indemnity and warranty terms
Construction, occupancy, protection, exposure.
What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.
- Construction
- Usually a small office, garage or home base, sometimes a leased unit in a light-industrial park, with service vans parked outside.
- Occupancy
- Storage of plastic pipe, fans, solvent cement, foam sealants and caulk, plus test monitors and core drills; little processing happens there.
- Protection
- Flammable adhesives kept in a metal cabinet, extinguishers, an intruder alarm and locked van parking; sprinklers are rare in these small units.
- Exposure
- The premises add little; the exposure sits in customers' basements, crawl spaces and roofs, often in older homes with gas appliances.
What to ask and look for.
Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.
Before quoting: ask the broker or owner
Documents to request
On site: work performed
On site: installation practice
On site: follow-up and records
On site: people
Refer or decline if you find
- No post-mitigation testing on record
- Guaranteed radon levels with no retest program
- Liability policy excluding radon or all pollutants
- Uncertified installers working unsupervised
- Exhaust terminating at ground level or under a deck
How UrbanStat data helps.
Demand follows local geology, and so do the consequences of a failed system. High water tables flood suction pits and burn out fans, ground movement reopens sealed slab cracks, and vans parked on residential streets lose tools and monitors.
- Flood scores at a job address flag basements where rising water could fill the suction pit and stop the fan.
- Parcel and permit data give the construction date and foundation changes of each building treated, which shape the mitigation method needed.
- Earthquake scores at treated addresses indicate where slab cracking may undo sealing work after handover.
What the published numbers say.
Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.
1.6 recordable injuries and illnesses per 100 full-time workers, below the private-industry average of 2.3.
0.6 of these cases per 100 workers involved days away from work.
United States, 2024. Industry: All other specialty trade contractors (NAICS 23899), the closest published group. Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.
33 fatal work injuries in 2024, most often from transportation incidents (13).
Deaths per 100,000 full-time equivalent workers, for the industry sector as a whole.
United States, private industry, 2024. Industry: All Other Specialty Trade Contractors (NAICS 23899), the closest published group. Source: U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries; sector rates.
1,052 citations from 362 inspections; 60% were classed serious, willful or repeat.
- 1910.1200 Hazard communication56
- 1926.501 Duty to have fall protection51
- 1926.451 General requirements (scaffolds)43
- 1910.134 Respiratory protection30
- 1926.1153 Respirable crystalline silica29
Standards cited most often in this industry, by number of citations.
United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: All Other Specialty Trade Contractors (NAICS 238990). Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).
3 facilities reported toxic chemical releases totaling 12,473 pounds on and off site.
- Hydrogen fluoride8,950
- Barium compounds2,671
- Manganese compounds532
Chemicals released in the largest amounts, in pounds.
United States, 2024. Industry: Remediation Services (NAICS 562910). Covers facilities in listed industries with ten or more full-time employees that handle listed chemicals above set thresholds. Source: U.S. Environmental Protection Agency, Toxics Release Inventory basic data files.
Industry loss ratios by line2020 to 2024, the same table on every guide
Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.
| Published line | Closest line in this guide | 2020 | 2021 | 2022 | 2023 | 2024 |
|---|---|---|---|---|---|---|
| Fire | Property | 63.2% | 67.3% | 62.4% | 45.5% | 40.9% |
| Commercial multiple peril | Property and liability sold as a package | 61.2% | 60.2% | 59.4% | 61.2% | 54.4% |
| Inland marine | Inland marine and equipment | 64.5% | 49.4% | 47.1% | 44.1% | 44.0% |
| Other liability | Premises liability, and most umbrella, professional (other than medical) and cyber cover | 65.1% | 58.8% | 61.0% | 63.7% | 71.2% |
| Products liability | Products and completed work | 48.2% | 52.2% | 46.0% | 57.5% | 60.3% |
| Workers’ compensation | Workers’ injury | 47.9% | 49.2% | 45.0% | 44.3% | 46.0% |
| Commercial auto liability | Commercial auto | 68.3% | 66.5% | 71.9% | 76.8% | 77.6% |
| Commercial auto physical damage | Commercial auto | 50.9% | 56.3% | 64.3% | 65.1% | 57.9% |
United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.
- Contractors pollution liability
- Many general liability forms treat radon as a pollutant and exclude it, so the firm needs cover that names it.
- Additional insured endorsements
- Home builders hiring systems for new houses demand additional insured status, waivers and primary wording.
- Hired and non-owned auto
- Technicians sometimes drive their own vehicles to estimates, tests and follow-up visits.
See this risk on the map.
Book a 30-minute walkthrough tailored to your portfolio and perils of interest.