Data centers and colocation facilities

Data centers house customers' servers and network gear in secure halls with redundant utility power, generators, battery backup and precision cooling, sold by the rack, cage or whole building with uptime guarantees. Electrical faults, cooling failures and battery fires turn quickly into outages that ripple through every tenant's business.

Information · NAICS 518210 · SIC 7374 · Updated November 2026

01 / Loss drivers

Where losses come from.

  1. 01

    Switchgear, transfer switch or generator failures that drop power to whole halls during a utility outage

  2. 02

    Lithium-ion battery or electrical room fires whose smoke and suppression shut down the building

  3. 03

    Tenant claims for outage losses and damaged equipment when uptime promises are broken

How it comparesEach line’s rating against the average for its NAICS sector, Information (23 business types), and for all 747.
  1. PropertyProperty: High, 4 of 5; sector average 2.7; all business types 2.9.
  2. Business interruptionBusiness interruption: Severe, 5 of 5; sector average 3.2; all business types 2.7.
  3. Premises liabilityPremises liability: Moderate, 2 of 5; sector average 2.3; all business types 2.7.
  4. Products and completed workProducts and completed work: Low, 1 of 5; sector average 1.9; all business types 2.6.
  5. Workers’ injuryWorkers’ injury: Moderate, 2 of 5; sector average 2.3; all business types 3.0.
  6. Commercial autoCommercial auto: Low, 1 of 5; sector average 2.2; all business types 2.5.
  7. Crime and theftCrime and theft: Moderate, 2 of 5; sector average 2.5; all business types 2.2.
  8. Inland marine and equipmentInland marine and equipment: Elevated, 3 of 5; sector average 3.0; all business types 2.6.
  9. EnvironmentalEnvironmental: Elevated, 3 of 5; sector average 1.7; all business types 2.3.
  10. Cyber and dataCyber and data: High, 4 of 5; sector average 3.4; all business types 2.7.
  11. Professional liabilityProfessional liability: High, 4 of 5; sector average 2.1; all business types 2.0.
  12. Umbrella and excessUmbrella and excess: Elevated, 3 of 5; sector average 2.9; all business types 3.6.
What’s changing
  • Artificial intelligence workloads push rack power densities far higher and bring liquid cooling into the hall, adding water and heat load beside costly equipment.
  • Lithium-ion batteries are replacing lead-acid backup, saving space but adding thermal runaway and off-gas hazards that older designs did not plan for.
  • Grid capacity limits push new campuses toward on-site gas turbines, fuel cells and battery storage, turning data centers into small power plants.
02 / Line by line

Twelve lines, rated.

Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.

Property

High
Megawatts of electrical plant, battery strings and generator fuel sit beside very high-value halls, where smoke alone can ruin equipment.

Fire, explosion, water and weather damage to buildings, contents and stock.

Watch for
  • Lithium-ion battery cabinets inside or next to data halls
  • Liquid cooling loops and chilled water piping over racks
  • Customer cages packed beyond the hall's design power density
Controls that matter
  • Battery rooms in fire-rated enclosures with off-gas detection and venting
  • Aspirating smoke detection with pre-action or clean-agent suppression in halls
  • Infrared scanning and maintenance of switchgear and busway on a schedule

Business interruption

Severe
An outage stops revenue across every tenant at once, and replacement transformers, switchgear and generators can take many months to arrive.

How long and how costly a shutdown is.

Watch for
  • Single utility feed or one substation serving the campus
  • No spare transformers or switchgear sections held or reserved
  • Tenant contracts allowing termination after a single major outage
Controls that matter
  • Redundant power paths tested under real load, not just on paper
  • Fuel supply contracts with priority delivery during regional emergencies
  • Critical spares stocked on site or reserved with suppliers

Premises liability

Moderate
Customer technicians and contractors work in the halls under escort, with trip, lifting and electrical hazards but few members of the public.

Injuries to customers and the public, on site or caused by operations elsewhere.

Watch for
  • Customer staff working unescorted in shared halls overnight
  • Raised floor tiles lifted during cabling work
Controls that matter
  • Escort and induction rules for all visitors and contractors
  • Barriers and work permits for any floor or ceiling opening

Products and completed work

Low
The business sells space, power and connectivity rather than goods; service failures fall under professional exposure.

Harm caused by what the business sells, serves, makes, installs or repairs.

Watch for
  • Hardware resold or installed for customers under the operator's name
Controls that matter
  • Manufacturer warranties passed through on any hardware resold

Workers’ injury

Moderate
Small technical crews face arc flash in switchgear rooms, heavy lifts of servers and batteries, and loud, cold halls.

Injuries and illness to employees.

Watch for
  • Live electrical work done to avoid planned outages
  • Night shifts with one technician on site
Controls that matter
  • Arc-flash studies, rated clothing and lockout for all electrical work
  • Server lifts and two-person rules for racking heavy equipment

Commercial auto

Low
Staff drive light vehicles between sites; fuel deliveries and heavy equipment moves are left to contractors.

Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.

Watch for
  • Operators running their own fuel trucks for generators
Controls that matter
  • Fuel delivered by licensed carriers under written contract

Crime and theft

Moderate
Strong physical security limits burglary, but insiders and contractors can remove drives, memory and graphics cards from customer racks.

Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.

Watch for
  • Contractors and customer staff with long-term unescorted access
  • Retired drives awaiting destruction stored in open cages
Controls that matter
  • Mantraps, badge and biometric entry, and camera coverage of every aisle
  • Drive destruction on site with a logged chain of custody

Inland marine and equipment

Elevated
Customers' servers, often worth more than the building, sit in the operator's care, and damage from an outage or fire brings claims.

Property in transit, at job sites or in the insured’s care, and mobile equipment.

Watch for
  • Contracts silent on liability for damage to customer equipment
  • Rented generators and chillers brought in during maintenance
Controls that matter
  • Colocation terms requiring customers to insure their own equipment
  • Waivers of subrogation between operator and customers

Environmental

Elevated
Large diesel stores for generators, refrigerants, battery electrolyte and cooling tower water treatment create spill and release exposure.

Pollution on or from the site or the work.

Watch for
  • Underground or single-wall diesel tanks feeding generator plant
  • Cooling towers without a water treatment and bacteria testing program
Controls that matter
  • Double-wall tanks with leak detection and spill kits at fill points
  • Water management plan with routine bacteria sampling for cooling towers

Cyber and data

High
Building management, power monitoring and access systems are networked, and an attack that disables cooling or power takes every tenant offline.

Data breaches, ransomware, system outages and attacks on connected equipment.

Watch for
  • Vendor remote access to cooling and power controls left always on
  • Building controls on the same network as the customer portal
Controls that matter
  • Building and power controls isolated from corporate and customer networks
  • Multi-factor, time-limited vendor access with session recording

Professional liability

High
Uptime and service promises are the product, so a failed transfer or cooling lapse brings claims for tenants' lost revenue.

Loss or injury caused by advice, design, testing, care or another professional service.

Watch for
  • Service credits or liability left uncapped in large tenant contracts
  • Managed hosting or remote hands work that changes customer systems
  • Maintenance switching on live power paths done from memory, without a second person
Controls that matter
  • Liability caps and consequential loss exclusions in every customer agreement
  • Change control and written work orders for all remote hands tasks
  • Written, peer-checked switching procedures for every maintenance operation on live plant

Umbrella and excess

Elevated
Few people are on site, but an outage hitting many tenants at once or an explosion during battery or generator work is severe.

How likely one liability event is to exhaust primary limits.

Watch for
  • Tenants running emergency, health or payment services from the site
Controls that matter
  • Customer contracts with mutual waivers and liability caps
03 / Property picture

Construction, occupancy, protection, exposure.

What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.

Construction
Purpose-built, windowless concrete or steel buildings, or converted warehouses and office blocks, with raised floors or overhead cable trays, rooftop or yard chillers, and generator yards.
Occupancy
High-density racks drawing power around the clock, switchgear and battery rooms, diesel generators with stored fuel, and cooling plant whose failure overheats a hall within minutes.
Protection
Aspirating smoke detection, pre-action sprinklers or clean agent in halls, fire-rated battery and electrical rooms, redundant power and cooling, round-the-clock staff, mantraps and cameras.
Exposure
Campuses cluster near substations and fiber routes, often beside other data centers and industrial sites; neighboring fires, utility failures and wildfire smoke affect several buildings at once.
04 / Checklist

What to ask and look for.

Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.

Before quoting: ask the broker or owner

Documents to request

On site: power and cooling

On site: fire protection

On site: security and access

On site: operations and records

Refer or decline if you find

  • Lithium-ion battery cabinets inside the data hall with no fire separation
  • Generators never tested under full building load
  • Single utility feed with no second substation path
  • Uncapped liability or service credits in major customer contracts
  • Deferred maintenance on switchgear or cooling plant at a full site
05 / Location

How UrbanStat data helps.

Low-lying sites flood electrical rooms and fuel systems, shaking damages racks and cooling plant, and regional storms cut grid power for days. Wildfire smoke clogs air intakes, and tornadoes threaten rooftop cooling.

FloodEarthquakeHurricaneWildfireTornado
  • Flood and earthquake scores at the address show whether switchgear, fuel systems and halls face water or shaking before property and interruption limits are set.
  • Street-by-street exposure views show the insured value building up on a campus of neighboring data halls, with alerts when a set threshold is passed.
  • Live hurricane tracks and wildfire perimeters show which insured data centers lie in an event's path, so fuel and staffing questions go to the right sites first.
Flood · Earthquake · Hurricane · Wildfire
06 / Public loss data

What the published numbers say.

Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.

Workers’ injury frequency

0.3 recordable injuries and illnesses per 100 full-time workers, below the private-industry average of 2.3.

Data processing, hosting, and related services
0.3
All private industry
2.3

0.1 of these cases per 100 workers involved days away from work.

United States, 2024. Industry: Data processing, hosting, and related services (NAICS 518), the closest published group. Source: U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024.

Workplace deaths

2 fatal work injuries in 2024.

United States, private industry, 2024. Industry: Lessors of Nonresidential Buildings (except Miniwarehouses) (NAICS 53112), the closest published group. Source: U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries.

Most cited safety standards

25 citations from 8 inspections; 72% were classed serious, willful or repeat.

  • 1910.335 Safeguards for personnel protection
    3
  • 1910.178 Powered industrial trucks
    2
  • 1910.332 Training (electrical)
    2
  • 1910.157 Portable fire extinguishers
    2
  • 1910.134 Respiratory protection
    2

Standards cited most often in this industry, by number of citations.

United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Computing Infrastructure Providers, Data Processing, Web Hosting, and Related Services (NAICS 518210). Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations); standard titles from the Code of Federal Regulations, Title 29 (section headings).

Fire frequency

7,966 fires a year reported in industrial and manufacturing properties, causing about $810 million in direct property damage a year.

United States, 2020 to 2024, annual average. The group includes utility, defense, agriculture and mining properties. Source: National Fire Protection Association, Structure Fires in Industrial and Manufacturing Properties.

Industry loss ratios by line2020 to 2024, the same table on every guide

Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.

Published lineClosest line in this guide20202021202220232024
FireProperty63.2%67.3%62.4%45.5%40.9%
Commercial multiple perilProperty and liability sold as a package61.2%60.2%59.4%61.2%54.4%
Inland marineInland marine and equipment64.5%49.4%47.1%44.1%44.0%
Other liabilityPremises liability, and most umbrella, professional (other than medical) and cyber cover65.1%58.8%61.0%63.7%71.2%
Products liabilityProducts and completed work48.2%52.2%46.0%57.5%60.3%
Workers’ compensationWorkers’ injury47.9%49.2%45.0%44.3%46.0%
Commercial auto liabilityCommercial auto68.3%66.5%71.9%76.8%77.6%
Commercial auto physical damageCommercial auto50.9%56.3%64.3%65.1%57.9%

United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary.

Coverages to raise
Equipment breakdown
Transformers, switchgear, chillers and uninterruptible power units fail without fire and cause the costliest outages.
Utility service interruption
A substation or grid failure off premises drains generator fuel, and standard forms limit off-premises power losses.
Builders risk
Campuses expand hall by hall, putting construction and commissioning work beside live, revenue-earning halls.
Contingent business interruption
A fiber carrier or fuel supplier failure can stop service though the building itself is undamaged.
Classification
SystemCodeIndustry
NAICS 2022, primary518210Computing Infrastructure Providers, Data Processing, Web Hosting, and Related Services
NAICS 2022531120Lessors of Nonresidential Buildings (except Miniwarehouses)
SIC 1987, primary7374Computer Processing and Data Preparation and Processing Services
SIC 19877379Computer Related Services, NEC
Next step

See this risk on the map.

Book a 30-minute walkthrough tailored to your portfolio and perils of interest.

Request a Demo →