---
title: "Insulation contractors (NAICS 238310, SIC 1742): Industry Risk Guide"
description: "NAICS 238310 · SIC 1742. Insulation contractors install batts, blown cellulose and fiberglass, rigid board and spray polyurethane foam in buildings, and…"
url: https://www.urbanstat.com/industry-risk-guides/insulation-contractors-naics-238310/
type: Industry risk guide: UrbanStat’s underwriting guide for one business type
publisher: UrbanStat
---

# Insulation contractors NAICS 238310 · SIC 1742

Insulation contractors install batts, blown cellulose and fiberglass, rigid board and spray polyurethane foam in buildings, and lag pipes, ducts and equipment. Spray foam brings reactive chemicals and fire risk during application, while retrofit work in old attics and walls meets wiring, vermiculite and asbestos.

[**NAICS 238310** Drywall and Insulation Contractors](https://www.urbanstat.com/industry-risk-guides/naics/#naics-238310) · [**SIC 1742** Plastering, Drywall, Acoustical, and Insulation Work](https://www.urbanstat.com/industry-risk-guides/sic/#sic-1742) · [**NAICS 238290** Other Building Equipment Contractors](https://www.urbanstat.com/industry-risk-guides/naics/#naics-238290)

Construction · Updated November 2026

Risk profile

1. [Property Elevated](#line-property)
2. [Business interruption Moderate](#line-bi)
3. [Premises liability Elevated](#line-gl)
4. [Products and completed work High](#line-products)
5. [Workers’ injury Elevated](#line-wc)
6. [Commercial auto Elevated](#line-auto)
7. [Crime and theft Low](#line-crime)
8. [Inland marine and equipment Elevated](#line-marine)
9. [Environmental Elevated](#line-env)
10. [Cyber and data Moderate](#line-cyber)
11. [Professional liability Moderate](#line-prof)
12. [Umbrella and excess High](#line-umbrella)

**Products and completed work.** Off-ratio foam smells for years, buried light fixtures and old wiring overheat, and badly placed insulation traps moisture and rots framing.

Loss drivers

## Where losses come from.

1. Fires during and after spray foam application, and from insulation packed over hot fixtures and old wiring
2. Odor, off-gassing and moisture problems that make a finished building unlivable
3. Falls through ceilings and respiratory injury to installers

How it compares Each line’s rating against the average for its NAICS sector, Construction (49 business types), and for all 747.

- Insulation contractors, colored by its rating
- Sector average
- All business types

**Low** **Moderate** **Elevated** **High** **Severe**

1. Property Property Property: Elevated, 3 of 5; sector average 2.2; all business types 2.9.
2. Business interruption Interruption Business interruption: Moderate, 2 of 5; sector average 1.8; all business types 2.7.
3. Premises liability Premises Premises liability: Elevated, 3 of 5; sector average 3.5; all business types 2.7.
4. Products and completed work Products Products and completed work: High, 4 of 5; sector average 3.8; all business types 2.6.
5. Workers’ injury Workers Workers’ injury: Elevated, 3 of 5; sector average 3.8; all business types 3.0.
6. Commercial auto Auto Commercial auto: Elevated, 3 of 5; sector average 3.1; all business types 2.5.
7. Crime and theft Crime Crime and theft: Low, 1 of 5; sector average 1.7; all business types 2.2.
8. Inland marine and equipment Marine Inland marine and equipment: Elevated, 3 of 5; sector average 3.2; all business types 2.6.
9. Environmental Environmental Environmental: Elevated, 3 of 5; sector average 2.5; all business types 2.3.
10. Cyber and data Cyber Cyber and data: Moderate, 2 of 5; sector average 2.0; all business types 2.7.
11. Professional liability Professional Professional liability: Moderate, 2 of 5; sector average 2.3; all business types 2.0.
12. Umbrella and excess Umbrella Umbrella and excess: High, 4 of 5; sector average 4.0; all business types 3.6.

What’s changing

- Tighter energy codes and incentives push more spray foam and dense-pack retrofit work, raising both fire and moisture claims on completed jobs.
- Lower-emission foam blowing agents and new chemistries change handling and cure behavior, so crews trained on older products make mistakes.
- Growing awareness of isocyanate sensitization and indoor air quality brings more occupant illness claims after spraying in occupied homes.

Line by line

## Twelve lines, rated.

Each line shows its rating and the reason for it; open a line for what to watch for and the controls that matter. Ratings are UrbanStat’s own editorial view of a typical business of this type, on a five-step scale. They are a starting point for questions, not a quote, a rate or a statistical measure.

### Property: Elevated (3 of 5)

Foam board, facings and drums of foam chemicals make a combustible warehouse, and spray rigs park inside overnight.

Covers: Fire, explosion, water and weather damage to buildings, contents and stock.

**Watch for**

- Spray rigs with heated hoses and generators stored indoors beside stock
- Foam board and bagged cellulose stacked to the roof
- Drums of isocyanate and resin kept without containment

**Controls that matter**

- Rigs parked outside or in a separated bay, with power off
- Storage height held within the sprinkler system's design
- Chemical drums on containment pallets at the stated storage temperature

### Business interruption: Moderate (2 of 5)

Materials are restocked quickly, but a lost spray rig takes months to replace in busy markets.

Covers: How long and how costly a shutdown is.

**Watch for**

- One or two rigs earning most of the revenue
- Single foam chemical supplier

**Controls that matter**

- Rigs parked apart so one fire cannot take all
- Rental or subcontract capacity arranged in advance

### Premises liability: Elevated (3 of 5)

Spray foam drifts onto cars and neighbors, fumes require occupants to leave, and foam sprayed too thick can self-heat and ignite.

Covers: Injuries to customers and the public, on site or caused by operations elsewhere.

**Watch for**

- Exterior or roof spraying in wind near parked vehicles
- Occupants allowed back before the stated re-entry time
- Thick passes applied to hit a deadline

**Controls that matter**

- Pass thickness limits followed, with cure time between lifts
- Written re-entry and ventilation instructions signed by the occupant
- Masking, wind limits and overspray recovery arrangements

### Products and completed work: High (4 of 5)

Off-ratio foam smells for years, buried light fixtures and old wiring overheat, and badly placed insulation traps moisture and rots framing.

Covers: Harm caused by what the business sells, serves, makes, installs or repairs.

**Watch for**

- Foam left exposed without the required thermal or ignition barrier
- Insulation blown over recessed lights, knob-and-tube wiring or flue pipes
- Roof decks and crawlspaces sealed without a moisture design

**Controls that matter**

- Installer certification from the foam manufacturer; ratio and temperature logs per job
- Pre-work survey of wiring, fixtures, flues and ventilation
- Barrier coatings applied and photographed before handover

### Workers’ injury: Elevated (3 of 5)

Installers crawl through hot attics and tight crawlspaces, step between joists, and breathe fibers and isocyanate vapor.

Covers: Injuries and illness to employees.

**Watch for**

- Spray foam applied without supplied-air respirators
- Attic work in summer heat with no time limits
- Stepping off joists onto bare ceiling board

**Controls that matter**

- Supplied-air respirators and full skin cover for sprayers and helpers
- Crawl boards in attics and planned heat breaks
- Medical surveillance for isocyanate sensitization

### Commercial auto: Elevated (3 of 5)

Box trucks and trailers carrying heated chemical tanks, generators and blowers go to a job site daily.

Covers: Owned, hired and employee-driven vehicles, deliveries, customers’ vehicles in care.

**Watch for**

- Heavy spray rig trailers towed by light trucks
- Chemicals transported without securing or documentation

**Controls that matter**

- Tow ratings checked and drivers trained on trailers
- Drums secured; spill kit and extinguisher on each rig
- Hired and non-owned auto cover for estimators driving their own cars

### Crime and theft: Low (1 of 5)

Customers pay by invoice or card and the materials have little resale value.

Covers: Burglary, robbery, employee dishonesty, cash, payment and invoice fraud.

**Watch for**

- Generators and compressors on rigs parked on the street

**Controls that matter**

- Rigs locked and parked in a fenced yard

### Inland marine and equipment: Elevated (3 of 5)

A spray rig is a truck or trailer packed with proportioner, heated hoses, generator and compressor, and it is the business.

Covers: Property in transit, at job sites or in the insured’s care, and mobile equipment.

**Watch for**

- Rigs valued well below replacement cost
- Fire originating in the rig's own heaters or generator

**Controls that matter**

- Each rig scheduled at current replacement value
- Extinguishers and shutdown checklist on board

### Environmental: Elevated (3 of 5)

Retrofit work disturbs asbestos and vermiculite, and spray chemicals, overspray and waste drums need controlled handling.

Covers: Pollution on or from the site or the work.

**Watch for**

- Old pipe lagging, boiler wrap or vermiculite attic fill removed by the crew
- Empty isocyanate drums discarded without neutralizing

**Controls that matter**

- Suspect materials sampled before work, with licensed abatement where positive
- Waste chemicals and drums returned through the supplier or a licensed hauler

### Cyber and data: Moderate (2 of 5)

Online leads, financing and energy-program paperwork put homeowners' personal and income data on the firm's systems.

Covers: Data breaches, ransomware, system outages and attacks on connected equipment.

**Watch for**

- Rebate or weatherization applications holding income records sent by email
- Estimating and scheduling on one laptop with no backup

**Controls that matter**

- Customer files on a managed system with multi-factor login
- Daily backups of estimating, scheduling and job photo records

### Professional liability: Moderate (2 of 5)

Energy audits, moisture advice and foam specifications are relied on by owners; bad advice leads to condensation, rot or failed energy savings.

Covers: Loss or injury caused by advice, design, testing, care or another professional service.

**Watch for**

- Energy audits or blower-door testing sold as a separate service
- Unvented attic or crawlspace conversions designed by the installer

**Controls that matter**

- Certified energy auditors and written report templates
- Moisture design checked by an engineer or designer for unusual assemblies

### Umbrella and excess: High (4 of 5)

A spray foam fire can destroy a large building, and off-gassing claims can involve whole families or many units.

Covers: How likely one liability event is to exhaust primary limits.

**Watch for**

- Spray foam in occupied multifamily buildings, schools or hospitals
- Tract or condominium contracts with the same foam detail repeated

**Controls that matter**

- Limits sized to the largest building sprayed
- Ignition barriers and re-entry rules enforced the same way on every job

Property picture

## Construction, occupancy, protection, exposure.

What a risk engineer expects to find at a typical site of this type, and what to compare a submission against.

- **Construction**: Usually a single-story metal or masonry warehouse with truck bays for spray rigs and blowing trucks, often in a light industrial park.
- **Occupancy**: Stock of foam board, faced batts, bagged cellulose and drums of foam chemicals, with rigs parked inside; foam plastics make it burn hot and fast.
- **Protection**: Sprinklers designed for foam plastic storage, monitored alarms, rigs in a separated bay or outside, and chemical drums kept at the stated temperature.
- **Exposure**: Shared walls in multi-tenant parks let a foam fire spread to neighbors; on job sites, overspray reaches cars and neighboring houses.

Checklist

## What to ask and look for.

Start with the desk review before quoting, then walk the site. Tick questions off as you go; ticks are kept in this browser only.

### Before quoting: ask the broker or owner

- What are annual revenue and payroll, and how many installers and spray rigs are in service?
- How many jobs are tract or multifamily contracts repeating one foam detail across many units?
- Does the firm perform energy audits or work under utility or public weatherization programs?
- Are spray foam jobs ever subcontracted, and are subcontractors held to the same logs and training?
- Has the firm ever had to remove foam from a building, and why?

### Documents to request

- Loss runs for the current and prior policy terms
- Spray foam job logs and installer certifications
- Sample builder and homeowner contracts
- Asbestos and vermiculite testing procedure and recent results
- Respirator fit-test and medical surveillance records

### On site: work performed

- Which materials are installed: batts, blown fiber, rigid board, spray foam, mechanical lagging?
- What share of revenue is spray foam, and is it open-cell, closed-cell or roofing foam?
- What is the mix of new construction, retrofit and commercial or industrial work?
- Does the firm remove old insulation, and who handles asbestos or vermiculite?

### On site: job sites

- What survey is done for wiring, recessed lights and flues before insulating?
- How are foam pass thickness, mix ratio and temperatures controlled and logged?
- When may occupants re-enter after spraying, and how is that communicated?
- Who applies thermal or ignition barriers over exposed foam?

### On site: people and equipment

- What respiratory protection do sprayers and helpers wear, and is fit testing current?
- Where are spray rigs parked overnight, and how are they shut down?
- What manufacturer training or certification do installers hold?

### On site: records and history

- Are job logs, photos and customer sign-offs kept for each project?
- What do past claims show for fires, odor complaints and overspray?

### Refer or decline if you find

- Spray foam applied by crews with no manufacturer training
- No job logs of foam ratio, temperature and thickness
- Exposed foam left without a fire barrier
- Vermiculite or asbestos insulation disturbed without testing
- Spray rigs stored inside the warehouse with stock

Location

## How UrbanStat data helps.

Fibrous and cellulose stock is ruined by any water, and a warehouse of foam board burns fiercely if wildfire embers or a neighboring fire reach it. Rigs parked outside carry generators and compressors thieves want.

Flood · Wildfire · Crime

- Flood scores at the warehouse address show whether bagged and fibrous stock that cannot be dried sits in water's path.
- Wildfire scores at the address indicate whether a building full of foam plastics lies within reach of embers.
- Crime scores at the yard address inform theft terms for spray rigs, generators and compressors parked outside.

[Request a Demo →](https://www.urbanstat.com/demo/) · [Risk Selection](https://www.urbanstat.com/products/risk-selection/)

Flood · Wildfire · Crime

Public loss data · NAICS 238310

## What the published numbers say.

Official statistics for the industry or property type closest to this business. They describe the industry as a whole, not any one insured.

Workers’ injury frequency

**2.9** recordable injuries and illnesses per 100 full-time workers, above the private-industry average of 2.3.

Drywall and insulation contractors

**2.9**

All private industry

**2.3**

1.2 of these cases per 100 workers involved days away from work.

United States, 2024. Industry: Drywall and insulation contractors (NAICS 23831), the closest published group. Source: [U.S. Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Table 1: incidence rates of nonfatal occupational injuries and illnesses by industry and case types, 2024](https://www.bls.gov/web/osh/table-1-industry-rates-national.htm).

Workplace deaths

**17** fatal work injuries in 2024, most often from falls, slips and trips (10).

Construction

**9.2**

All workers

**3.3**

Deaths per 100,000 full-time equivalent workers, for the industry sector as a whole.

United States, private industry, 2024. Industry: Drywall and Insulation Contractors (NAICS 23831), the closest published group. Source: [U.S. Bureau of Labor Statistics, Census of Fatal Occupational Injuries](https://www.bls.gov/iif/fatal-injuries-tables/fatal-occupational-injuries-table-a-1-2024.htm); [sector rates](https://www.bls.gov/charts/census-of-fatal-occupational-injuries/number-and-rate-of-fatal-work-injuries-by-industry.htm).

Most cited safety standards

**874** citations from 317 inspections; 57% were classed serious, willful or repeat.

- 1926.451 General requirements (scaffolds) **72**
- 1926.501 Duty to have fall protection **58**
- 1910.134 Respiratory protection **50**
- 1910.1200 Hazard communication **31**
- 1926.1053 Ladders **30**

Standards cited most often in this industry, by number of citations.

United States, citations issued October 2024 to September 2025 (federal fiscal year 2025). Industry: Drywall and Insulation Contractors (NAICS 238310). Covers federal and state-plan inspections. A citation is one violation item; one inspection can produce several. Source: [U.S. Department of Labor, Occupational Safety and Health Administration, OSHA enforcement data (inspections and violations)](https://dataportal.dol.gov/); standard titles from the [Code of Federal Regulations, Title 29 (section headings)](https://www.ecfr.gov/current/title-29).

**Industry loss ratios by line** (2020 to 2024, the same table on every guide)

Loss ratios are published by line of insurance, not by business type. They show how each line has run for insurers as a whole, whatever the business insured.

| Published line | Closest line in this guide | 2020 | 2021 | 2022 | 2023 | 2024 |
| --- | --- | --- | --- | --- | --- | --- |
| Fire | Property | 63.2% | 67.3% | 62.4% | 45.5% | 40.9% |
| Commercial multiple peril | Property and liability sold as a package | 61.2% | 60.2% | 59.4% | 61.2% | 54.4% |
| Inland marine | Inland marine and equipment | 64.5% | 49.4% | 47.1% | 44.1% | 44.0% |
| Other liability | Premises liability, and most umbrella, professional (other than medical) and cyber cover | 65.1% | 58.8% | 61.0% | 63.7% | 71.2% |
| Products liability | Products and completed work | 48.2% | 52.2% | 46.0% | 57.5% | 60.3% |
| Workers’ compensation | Workers’ injury | 47.9% | 49.2% | 45.0% | 44.3% | 46.0% |
| Commercial auto liability | Commercial auto | 68.3% | 66.5% | 71.9% | 76.8% | 77.6% |
| Commercial auto physical damage | Commercial auto | 50.9% | 56.3% | 64.3% | 65.1% | 57.9% |

United States. Losses incurred as a percent of direct premiums earned, countrywide, before reinsurance and not including loss adjustment expense. Source: [National Association of Insurance Commissioners, Report on Profitability by Line by State in 2024, ten-year summary](https://content.naic.org/sites/default/files/publication-pbl-pb-profitability-line-state.pdf).

Coverages to raise

- **Contractors' pollution liability**: Disturbed asbestos and vermiculite, isocyanate overspray and off-gassing are pollution claims that general liability often excludes.
- **Equipment breakdown**: A failed proportioner, heater or generator idles a spray rig and its crew until parts arrive.
- **Installation floater**: Foam board, batts and chemical drums staged at job sites are lost to fire, water or theft before acceptance.

## NAICS and SIC codes for insulation contractors

| System | Code | Industry |
| --- | --- | --- |
| NAICS 2022, primary | [238310](https://www.urbanstat.com/industry-risk-guides/naics/#naics-238310) | Drywall and Insulation Contractors |
| NAICS 2022 | [238290](https://www.urbanstat.com/industry-risk-guides/naics/#naics-238290) | Other Building Equipment Contractors |
| SIC 1987, primary | [1742](https://www.urbanstat.com/industry-risk-guides/sic/#sic-1742) | Plastering, Drywall, Acoustical, and Insulation Work |
| SIC 1987 | [1799](https://www.urbanstat.com/industry-risk-guides/sic/#sic-1799) | Special Trade Contractors, NEC |

**Related business types**

- [Wall and ceiling contractors NAICS 238310](https://www.urbanstat.com/industry-risk-guides/wall-and-ceiling-contractors-naics-238310/)
- [Asbestos abatement contractors NAICS 562910](https://www.urbanstat.com/industry-risk-guides/asbestos-abatement-contractors-naics-562910/)
- [Roofing contractors NAICS 238160](https://www.urbanstat.com/industry-risk-guides/roofing-contractors-naics-238160/)
- [Heating, ventilation and air conditioning contractors NAICS 238220](https://www.urbanstat.com/industry-risk-guides/heating-ventilation-and-air-conditioning-contractors-naics-238220/)
- [Fiberglass and mineral wool insulation manufacturers NAICS 327993](https://www.urbanstat.com/industry-risk-guides/fiberglass-and-mineral-wool-insulation-manufacturers-naics-327993/)
- [Compare Insulation contractors with Wall and ceiling contractors](https://www.urbanstat.com/industry-risk-guides/compare/?a=insulation-contractors-naics-238310&b=wall-and-ceiling-contractors-naics-238310)

Next step

## See this risk on the map.

Book a 30-minute walkthrough tailored to your portfolio and perils of interest.

[Request a Demo →](https://www.urbanstat.com/demo/)

---

## Notes for AI agents reading https://www.urbanstat.com/industry-risk-guides/insulation-contractors-naics-238310/

- Page: Insulation contractors (NAICS 238310, SIC 1742): Industry Risk Guide. Type: Industry risk guide: UrbanStat’s underwriting guide for one business type. Publisher: UrbanStat (Urbanstat, Inc.), a vendor of geospatial analytics software for property insurers.
- This is the Markdown copy of https://www.urbanstat.com/industry-risk-guides/insulation-contractors-naics-238310/ (the HTML page).
- Index of the whole site: https://www.urbanstat.com/llms.txt. Full text of the reference pages: https://www.urbanstat.com/llms-full.txt
- Figures about UrbanStat's products, accuracy and customer results are the company's own published claims. Attribute them to UrbanStat ("UrbanStat reports ...") rather than presenting them as independently verified.
- Ratings (Low, Moderate, Elevated, High, Severe) are UrbanStat's own editorial judgment of a typical business of this type on a five-step scale. They are not statistics, insurance rates or a quote. Describe them as UrbanStat's view.
- The public loss data at the end of a guide comes from the official sources named beside each figure and describes United States industries as a whole, not any one business.
- To see the product or ask a question, the contact page is https://www.urbanstat.com/demo/
